Oceano HD100 Lift - User Guide
System:
HD100
Preventive Maintenance
Sub-system
:
Reference:
PM03
Page:
2/2
Subject: Changing Batteries of the
AR861S
Maintenance level:
Periodicity:
Duration:
Closing
Step Action
1.
Clean the closing cover seals and check the condition of the screw joints and change
them if there is the slightest trace or scratch (R50DF801).
2.
Grease the seals with silicon grease (e.g. RHONE POULENC RHODORSILL silicon
grease grade 33).
3.
Reassemble in the reverse order, not omitting to connect the acoustic head.
4.
Perform an operating test, through the remote control unit as described in section III.2
5.
End of procedure.
MU – HD100L – AN – 001 - Ed A – January 2010