The IXL Tastic range has been designed to exacting standards to give you many years of trouble-free 

operation. To ensure you get the most from your Tastic there are a few simple points to keep in mind.

HEAT LAMPS

The IXL Tastic Heat Lamps have no warm up period because the infra red lamps provide instantaneous 

heat, and are designed to heat you and not your bathroom - that’s the efficient way infra red heat 

works. You’ll save money and energy, with an average cost of around one cent a shower if used 

correctly, (based on average 5 minute drying time). Also, to get the full benefit of Tastic’s infra red 

warmth, stand directly under the heat lamps. IXL’s exclusive clear heat lamps have been designed 

specifically for this application, and concentrate their heat for maximum effectiveness. 
Make sure you have the Tastic model that suits your bathroom ceiling height. This Tastic is 

manufactured to offer peak performance with bathroom ceiling heights up to 2.4 m for the Triumph 

11341, 2.7 m for the Sensation 12343 and 3.3 m for the Silhouette 12341.
The Tastic half heat function is available on the 4 lamp models, and is another energy saver, allowing 

you to adjust the heat level to suit prevailing conditions or personal preference.

VENTILATION

To ensure optimum performance of the exhaust fan, it is essential that there is adequate air flow into 

your bathroom to help the Tastic’s powerful and efficient exhaust fan to quickly remove steam while 

you shower. Your Tastic works by drawing steam-laden air from the room, and as with all exhaust fans 

it is essential that sufficient air inlet is provided. Ensure adequate inlets exist through windows, vents 

or under the door. Air flow path from inlet to fan should ideally pass over the steam source.

CENTRE LIGHT

The centre light in all Tastic models is designed to provide general illumination in your bathroom.  

For specific tasks like shaving or putting make-up on, you may need extra lighting to suit your 

individual needs.
Heat lamps can also be used to provide additional bright illumination for your bathroom. Lighter 

coloured walls and decor also help brighten your bathroom by reflecting more light.

Содержание Eco Tastic 12343

Страница 1: ...at Vent Light Eco Tastic Model 11341 Eco Triumph Model 12343 Eco Sensation Model 12341 Eco Silhouette Electrical Rating 230 240 V 50 Hz Model 12341 Eco Silhouette Model 12343 Eco Sensation Model 11341...

Страница 2: ...ximum life and value from it Our warranty depends on you using the Tastic according to this user guide It will only take you a few minutes so please read on Contents Eco Tastic Range Pg 3 Safety Pg 4...

Страница 3: ...257m3 hr or 72l s 12343 Eco Sensation 4 x 275 W Heat Vent Light 15 W CFL Centre Globe Half Heat Function Cutout 330 mm x 330 mm 200 mm Fan 348m3 hr or 97l s 12341 Eco Silhouette 4 x 375 W Heat Vent Li...

Страница 4: ...stic lamp surround in position This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they...

Страница 5: ...e Triumph 11341 2 7 m for the Sensation 12343 and 3 3 m for the Silhouette 12341 The Tastic half heat function is available on the 4 lamp models and is another energy saver allowing you to adjust the...

Страница 6: ...cavity itself should be well ventilated to outside so that moist air can be removed Local building codes may require flueing to outside through roof or as per Fig 5 page 8 for flat roof installation W...

Страница 7: ...batts Figure 3 measurement A Model No 11341 75 mm min where there is good ventilation to the sides of the unit 100 mm min where ventilation to the sides of the unit is restricted Model No s 12341 123...

Страница 8: ...the same fan switch as the Tastic see circuit diagrams NOTE S W A FAN LOW connection is the permanent active supply to the unit It must be provided so the unit can function as it was designed to do s...

Страница 9: ...er AS NZS 3000 not supplied 12341 6 5A 50Hz 12343 4 8A 50Hz ACTIVE EARTH NEUTRAL C C C C 2 2 2 2 1 1 1 1 Terminal Block 7 way Thermal Fuse Thermal Switch 330 Ohm 20 W Ceramic Resistor Terminal Block 2...

Страница 10: ...available for the Tastic it may be necessary to provide extra strengthening Eco Triumph approx 2 kg Eco Sensation Eco Silhouette approx 3 5 kg IMPORTANT Joists beams and rafters shall not be cut or no...

Страница 11: ...lectric cables do not rest over the Tastic 5 To secure the Tastic in position push lower ends of springs apart Fig 10 Ceiling board thickness should be adjusted to enable springs to be fitted without...

Страница 12: ...ation 275 watts max IXL Cat no 11300 NOTE Replace only with genuine IXL approved Hard Glass Infra Red lamps Light Bulb 15 W CFL IXL Cat no 12280 Light bulb is not covered by manufacturer s warranty Cl...

Страница 13: ...th 375 watt lamps A You can only use heat lamps which have been fitted and approved for use in your product The rating label will state the maximum wattage for your product Q What is the maximum recom...

Страница 14: ...itional ventilation We recommend that you visit our website for further details and suggestions on effectively ventilating your bathroom Q Can the installer rotate the IXL wall switch mechanisms A Yes...

Страница 15: ...Fan Tastic 2 in 1 Heat and Light Ducted Tastics Ventilation Fans Ventilation and Light Units Eco Tastics Remote controlled Tastics Smart Switch Easy Duct Thermal Transfer System Tastic Neo IXL Range A...

Страница 16: ...n equivalent current model where the balance of the warranty period from the original date of purchase will take effect 4 To the fullest extent permitted by law and subject always to Point 1 Sampford...

Страница 17: ...enabling a Sampford IXL assessment b submit proof of purchase with your claim eg tax invoice or purchase receipt c where a property has been constructed by a builder developer and it is fitted with I...

Страница 18: ...18 Record Your Model Tastic RECORD THE DETAILS OF YOUR MODEL AND KEEP THE FOLLOWING INFORMATION DO NOT SEND THIS TO IXL Installed By Suburb Date of Purchase Model No Serial No...

Страница 19: ...Notes Tastic...

Страница 20: ...d IXL Pty Ltd Service Department 421 Smith St Fitzroy Victoria 3065 Australia Phone 1300 727 421 Fax 1300 727 425 aftersalesservice sampfordixl com au info sampfordixl com au www sampfordixl com au Ap...

Отзывы: