background image

Warranty

Tastic

®

e.  will not cover any damages or problems caused to this product by natural forces eg. storm, 

fire, flood, and earthquake; or by intrusion or accumulation (or both) of foreign matters 

eg. dust, soil, and moisture. Sampford IXL recommends that you take out appropriate 

insurances to protect your product to this end;

f.   will not apply if this product is installed in a mobile dwelling eg. caravan or boat;

g.  will not apply if this product is removed from the location where it was first installed;

h.  is immediately void if the serial or model number label is removed or defaced;

i.   is immediately void if the product is serviced or repaired by an unauthorised/unqualified 

personnel;

j.   covers use of this product for domestic use only;

k.  will not be restarted or extended upon repair or replacement of the product or a part.

How to make a Claim under Your IXL Warranty  

7.  To make a claim under this Warranty you will need to: 

a.  contact Sampford IXL service department on 1300 727 421 or  

[email protected] to provide details and register your claim  

enabling a Sampford IXL assessment;

b.  submit proof of purchase with your claim eg. tax invoice or purchase receipt;

c.  where a property has been constructed by a builder/developer and it is fitted with IXL 

products, please submit proof of purchase by way of the certificate of occupancy,  

with your claim.

8.   Sampford IXL will contact you to make arrangements for service on site.

9.   Subject to Point 1, you will be responsible for any costs relating to the provision of your product 

to a Sampford IXL Authorised Service Dealer.

10.  Subject to Point 1, in the event you live more than 50 km from a Sampford IXL Authorised 

Service Dealer you may be subject to travel or transport costs to facilitate the repairing or 

replacement of your IXL product.

11.  Sampford IXL and its Authorised Service Dealers reserve the right to seek reimbursement of 

any costs incurred by them should your IXL product be found to be in good working order.

Privacy

The privacy of your personal information has always been important to us. To learn more about  

how we collect, keep and use your personal information, please obtain a copy of our privacy  

statement by visiting our website at www.sampfordixl.com.au or by contacting us via email on  

[email protected] or by telephone on 1300 727 421.

Содержание Eco Tastic 12343

Страница 1: ...at Vent Light Eco Tastic Model 11341 Eco Triumph Model 12343 Eco Sensation Model 12341 Eco Silhouette Electrical Rating 230 240 V 50 Hz Model 12341 Eco Silhouette Model 12343 Eco Sensation Model 11341...

Страница 2: ...ximum life and value from it Our warranty depends on you using the Tastic according to this user guide It will only take you a few minutes so please read on Contents Eco Tastic Range Pg 3 Safety Pg 4...

Страница 3: ...257m3 hr or 72l s 12343 Eco Sensation 4 x 275 W Heat Vent Light 15 W CFL Centre Globe Half Heat Function Cutout 330 mm x 330 mm 200 mm Fan 348m3 hr or 97l s 12341 Eco Silhouette 4 x 375 W Heat Vent Li...

Страница 4: ...stic lamp surround in position This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they...

Страница 5: ...e Triumph 11341 2 7 m for the Sensation 12343 and 3 3 m for the Silhouette 12341 The Tastic half heat function is available on the 4 lamp models and is another energy saver allowing you to adjust the...

Страница 6: ...cavity itself should be well ventilated to outside so that moist air can be removed Local building codes may require flueing to outside through roof or as per Fig 5 page 8 for flat roof installation W...

Страница 7: ...batts Figure 3 measurement A Model No 11341 75 mm min where there is good ventilation to the sides of the unit 100 mm min where ventilation to the sides of the unit is restricted Model No s 12341 123...

Страница 8: ...the same fan switch as the Tastic see circuit diagrams NOTE S W A FAN LOW connection is the permanent active supply to the unit It must be provided so the unit can function as it was designed to do s...

Страница 9: ...er AS NZS 3000 not supplied 12341 6 5A 50Hz 12343 4 8A 50Hz ACTIVE EARTH NEUTRAL C C C C 2 2 2 2 1 1 1 1 Terminal Block 7 way Thermal Fuse Thermal Switch 330 Ohm 20 W Ceramic Resistor Terminal Block 2...

Страница 10: ...available for the Tastic it may be necessary to provide extra strengthening Eco Triumph approx 2 kg Eco Sensation Eco Silhouette approx 3 5 kg IMPORTANT Joists beams and rafters shall not be cut or no...

Страница 11: ...lectric cables do not rest over the Tastic 5 To secure the Tastic in position push lower ends of springs apart Fig 10 Ceiling board thickness should be adjusted to enable springs to be fitted without...

Страница 12: ...ation 275 watts max IXL Cat no 11300 NOTE Replace only with genuine IXL approved Hard Glass Infra Red lamps Light Bulb 15 W CFL IXL Cat no 12280 Light bulb is not covered by manufacturer s warranty Cl...

Страница 13: ...th 375 watt lamps A You can only use heat lamps which have been fitted and approved for use in your product The rating label will state the maximum wattage for your product Q What is the maximum recom...

Страница 14: ...itional ventilation We recommend that you visit our website for further details and suggestions on effectively ventilating your bathroom Q Can the installer rotate the IXL wall switch mechanisms A Yes...

Страница 15: ...Fan Tastic 2 in 1 Heat and Light Ducted Tastics Ventilation Fans Ventilation and Light Units Eco Tastics Remote controlled Tastics Smart Switch Easy Duct Thermal Transfer System Tastic Neo IXL Range A...

Страница 16: ...n equivalent current model where the balance of the warranty period from the original date of purchase will take effect 4 To the fullest extent permitted by law and subject always to Point 1 Sampford...

Страница 17: ...enabling a Sampford IXL assessment b submit proof of purchase with your claim eg tax invoice or purchase receipt c where a property has been constructed by a builder developer and it is fitted with I...

Страница 18: ...18 Record Your Model Tastic RECORD THE DETAILS OF YOUR MODEL AND KEEP THE FOLLOWING INFORMATION DO NOT SEND THIS TO IXL Installed By Suburb Date of Purchase Model No Serial No...

Страница 19: ...Notes Tastic...

Страница 20: ...d IXL Pty Ltd Service Department 421 Smith St Fitzroy Victoria 3065 Australia Phone 1300 727 421 Fax 1300 727 425 aftersalesservice sampfordixl com au info sampfordixl com au www sampfordixl com au Ap...