background image

USER MANUAL

USER MANUAL

AIRBLAZE

FIREPLACE BLOWER SYSTEM

Summary of Contents for AC-FBA10

Page 1: ...USER MANUAL USER MANUAL AIRBLAZE FIREPLACE BLOWER SYSTEM ...

Page 2: ......

Page 3: ...roduct quality and friendly customer service If you have any questions or suggestions please don t hesitate to contact us Visit www acinfinity com and click contact for our contact information EMAIL support acinfinity com WEB www acinfinity com LOCATION Los Angeles CA ...

Page 4: ...863 00819137020870 00819137020887 MANUAL CODE 1810X1 SERIOUS INJURY OR DEATH Please do not touch the blower s impeller and blades Secure all nearby objects including wires and cables from coming into contact with the blower s impeller and blades Use caution when deciding where to install this blower ...

Page 5: ...5 MANUAL INDEX Manual Index Key Features Product Contents Mounting Powering Programming Other AC Infinity Products Warranty Page 5 Page 6 Page 7 Page 8 Page 11 Page 13 Page 21 Page 22 ...

Page 6: ...eller is suspended in mid air with four silicone rubber rivets to absorb vibrations and reduce blower noise DUAL BALL BEARINGS Fans contain long life ball bearings rated at 67 000 hours Also enables fans to be mounted in any direction PRECISE PROBE The corded probe is constructed of stainless steel to ensure precise temperature and humidity readings IP 32 PROTECTION The blower unit is sealed to In...

Page 7: ...7 PRODUCT CONTENTS AIRBLAZE FIREPLACE BLOWER SYSTEM Included in all series SENSOR PROBE x1 WOOD SCREW x3 MOUNTING SCREWS x3 VELCRO STRIPS x2 x3 x4 POWER ADAPTER x1 UNIVERSAL CONTROLLER x1 BLOWER UNIT x1 ...

Page 8: ... the lower half of the fireplace vent plate Clean the inside of the area of any dust or dirt STEP 2 While very carefully placing the blower towards the rear be sure the opening of the fan in which the air blows out is facing up and the rubber feet are facing the floor Avoid any gas lines or electrical wires that are already in place ...

Page 9: ...f the drilling area Use a power drill to mount the fan in place with the included screws to reduce any unwanted vibrations STEP 3 Be sure the metal plate is placed towards the wall of the vent and the rubber feet are placed against the floor with the fan blades facing forward as pictured in the illustration ...

Page 10: ... the outside of the vent away from the fireplace and use the included screw sets Use a drill to screw the controller into place STEP 6 Once the fan and Universal Controller are securely mounted with in a safe distance you are now able to continue to powering ...

Page 11: ...ing the blower s spinning impeller and blades POWERING STEP 2 Plug in the thermal probe directly under the controller the probe has to be placed with in the same area as the blower underneath the fireplace The probe should be able to detect heat once the fire place is on to start the blower Please make sure the this cord is secured away from contacting the blower s spinning impeller and blades ...

Page 12: ...celerates air being moved from the bottom of the fireplace vents through the fire place and exhausting out the top The heated air that the fireplace created will circulate back into the room at a faster face and warm up a larger area STEP 3 To power the device plug the adapter pin into the Universal controller and the prong end into the outlet inside the fire place or outside the fireplace if ther...

Page 13: ...luding alarms and screen lock 9 SETTING Displays the value you have set for the current mode Press the up or down button to change 7 PROBE HUMIDITY Displays the current humidity that the corded sensor probe is measuring Shows if no probe is plugged in 5 CONTROLLER MODE This area displays the mode that the controller is currently in Press the Mode Button to cycle through the modes 3 LEAF BUTTON Thi...

Page 14: ...lay s units F or C PROGRAMMING MODE SETTING Press the Mode button to cycle through the controller s available programming modes and settings ON Mode OFF Mode TIMER Mode AUTO Mode 4 triggers ALARM Settings 4 settings TIMER MODE In this mode press the up or down button to set a time for the timer The fans will run at the speed set in ON Mode until the timer s clock runs out in which the fans will st...

Page 15: ... this mode press the up or down button to set a low temperature trigger The fans will activate if the probe s measured temperature falls below the temperature you have set in this mode The activated fans will slowly increase in speed until it reaches the speed set in ON Mode Whenever the measured temperature rises above your set temperature the fans will slowly decrease in speed until the fans sto...

Page 16: ...this mode press the up or down button to set a low humidity trigger The fans will activate if the probe s measured humidity falls below the humidity you have set in this mode The activated fans will slowly increase in speed until it reaches the speed set in ON Mode Whenever the measured humidity rises above your set temperature the fans will slowly decrease in speed until the fans stop You may als...

Page 17: ...alarm triggers can only activate in AUTO ON or TIMER Mode Please leave ALARM SETTING to arm the controller ALARM SETTING LOW TEMP In this settings mode press the up and down button to set a low temperature alarm The alarm will activate if the probe s measured tem perature falls below the temperature you have set in this mode When the alarm triggers the fan will start spinning gradually to max spee...

Page 18: ...LOW HUMID In this settings mode press the up and down button to set a low temperature alarm The alarm will activate if the probe s measured tem perature falls below the temperature you have set in this mode When the alarm triggers the fan will start spinning gradually to max speed regardless of your other settings You may also hold the up and down button simultaneously to turn off this alarm in wh...

Page 19: ...To adjust the temperature that the probe sensor is measuring please press the MODE and UP button simultaneously This can be done while the controller is any mode or setting The calibration cycle ranges from 8 F to 8 F or 4 C to 4 C and will be applied to the probe sensor s measure ments HUMIDITY CALIBRATION To adjust the humidity that the probe sensor is measuring please press the MODE and DOWN bu...

Page 20: ...that you have set has been triggered HUMIDITY ALARM ALERT This icon will flash when the high or low humidity alarm that you have set has been triggered DISPLAY LOCK ALERT This icon is visible when the controller has been locked The icon will flash to alert you that the controller is locked if you try to change the mode or settings ALERT ICONS On the top left of the display is the alert icon sectio...

Page 21: ...t fans designed to quietly ventilate AV rooms and closets as well as various DIY air circulation and exhaust projects Features a thermal controller with intelligent programming that will automatically adjust duct fan speeds in re sponse to changing temperatures Crawlspace Fans The AIRTITAN is a line of weather proof fans designed to provide ventilation odor and moisture control for crawl spaces an...

Page 22: ...nity The program covers products that have become defective malfunctioned or expressively if the product becomes unusable The warranty program goes into effect on the date of purchase The program will expire two years from the date of purchase If your product becomes defective during that period AC Infinity will replace your product with a new one or issue you a full refund The warranty program do...

Page 23: ......

Page 24: ... part of the materials including graphics or logos available in this booklet may be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without specific permission from AC Infinity Inc ...

Page 25: ......

Page 26: ...www acinfinity com ...

Reviews: