2.3.6.6 Set up the communication speed
This function is for monitoring the output data of the power supply by using a computer. When you select
BAUDRATE SET function, the LCD will display as:
Users can change the communication setup by using the UP and DOWN
keys or by rotating the ROTARY knob, and confirm the value by pressing
the “Enter” button.
BAUDRATE 4800 represents BAUDRATE=4800bps
BAUDRATE 9600 represents BAUDRATE=9600bps
BAUDRATE 19200 represents BAUDRATE=19200bps
BAUDRATE 38400 represents BAUDRATE=38400bps
2.3.6.7 Set up communication address (0~31)
This communication address function is for monitoring multi-power supply systems. In the system, one
computer can monitor 32 power supplies at the most by the connecting a RS232 and
485 bus. Each power supply should have a unique address.
When you select ADDRESS SET function, the LCD will display as:
Users can change the communication address by pressing the keypad or
rotating the ROTARY knob, and confirm the value by pressing “Enter”
button. The range of the address is from 0 to 31.
2.3.6.8 Lock the keypad
When the keypad is locked you must enter the correct password to unlock it.
When you select the KEY LOCK function, the LCD will display as:
Users can enter 4 numbers or letters as the password by pressing the
number button or by using the ROTARY knob
and
keys to change the
number or ASCII code which will be your password, and confirm the
password by pressing the “Enter” button.
2.3.6.9 Clear saved parameters
When you select CLEAR SAVE DATA function, the LCD will display as:
* “*” refers to the serial number of the saved parameters.
2.3.6.10 Exit
Select “Exit” to exit the menu.