Chapter 2 Operation
2.1 General operation
1. Connect the power supply with PC using the 3311 adaptor
2.2 Function introduction
2.2.1. Main functions
1. Set up voltage
2. Set up current
3. Enable/disable the output
4. Store
parameters
5. Recall parameters
2.2.2 Sub-functions
1. Set up the maximum output voltage
2. Set up the maximum output power
3. Enable/disable the rotary knob
4. Set up initial output state
5. Save voltage setting
6. Set up the communication speed
7. Set up the communication address
8. Lock the keypad
9. Clear saved parameters
2.3 The operation of the function
There are 5 main functions and 9 sub-functions of this power supply please refer to the operation of these
functions as follows:
2.3.1 Set up voltage
The PGPS-36V3A power supply provides two methods to set up the output voltage: by the number keypad
and by the rotary knob. Please see the following operation procedure.
Procedure Operation details
LCD display
Step 1
Press the “V-set”
ENTER
PASSWORD
Step 2
Enter the password ( Or jump to step 4 if
the keypad is unlocked)
ENTER
PASSWORD
Step 3
Press the “Enter” button ( it will return to
step 2 if your password is wrong for
reentering)
ENTER
PASSWORD****
Step 4
Press the “V-set”. Set the voltage to 24.00V
by using the number key or the rotary knob.
SET VOLT=
0.000VNEW=