74
Specifications/Outer dimensions
Specifications
Information in this section is subject to change without notice.
■ Pump
Model code
Flow rate
L/H
(GPH)
Max.
discharge
pressure
MPa
(psi)
Avg. power
consump
-
tion
W
Current
value
A
Connection
Weight
kg
IX-D150 TC/TE
N
0.2-150
(0.05-39.6)
1.0
(145)
110
1.3
3/4-14NPT
14.5
FA
ANSI 150Lb 3/4"
14.5
IX-D150 S6
N
3/4-14NPT
15
FA
ANSI 150Lb 3/4"
17
IX-D300 TC/TE
N
0.4-300
(0.10-79.2)
0.5
(72.5)
110
1.3
1-11.5NPT
15.5
FA
ANSI 150Lb 1"
15.5
IX-D300 S6
N
1-11.5NPT
17
FA
ANSI 150Lb 1"
19.5
*The above information is based on pumping clean water at rated voltage and ambient temperature.
* Pressure overload protection will stop operation when a discharge pressure has risen 1.3 to 2 times higher than the maxi
-
mum level.
*Allowable room temperature: 0-50°C (32-122°F)
*Allowable liquid temperature: 0-50°C (32-122°F) for the TC/TE type, 0-80°C (32-176°F) for the S6 type
*Allowable power voltage deviation: Within ±10% of the rated range
*Ambient humidity: 30-90%RH (non condensing)
* When running the IX-D150 S6 at or below 1.0L/H or the IX-D300 S6 at or below 2.0L/H, an actual flow rate may not meet
a target rate.
■ Power cable
Conduction section area
18AWG Triplex cable (L/N/PE)
Length
2000 [mm]
Standard
U type : SJT W-A
U2 type : SJT W
Terminal treatment
Plug
■ Body colour
Blue
Munsell colour system 7.5PB 3/8
Specifications/Outer dimensions