4. INSTALLATION
Position and Mounting
For maximum effectiveness, position the Fantom Wide Blower as close as possible to
the charged surface to be neutralized. Direct the air stream longitudinally, and in the
same direction as, the target material movement to maximize the time the charged
surface remains in the air stream. Ensure that the ionized air stream covers the entire
target surface, and that the material to be neutralized is not in direct contact with a
background surface (such as a roller or laying on a tabletop). For best results, the
material to be neutralized should be in free air.
The Fantom can be placed on any flat, level surface. It can also be secured using the
(4) large truss head screws on the bottom of the unit. The (4) large truss head screws
thread directly into the internal fan frame, providing a secure mounting.
Figure 1. Hole Pattern on Bottom of Unit (top view of unit)
Electrical Connections
Depending on the model, the Fantom Wide Blower requires 120 VAC or 230 VAC,
50/60 HZ. Connect line cord to a grounded receptacle. If an extension cord is used,
it must be a 3-wire type providing electrical ground to the unit.
NOTE
– Do not attempt to operate at voltages other than those specified.