18
IQ Power Fantom
5201292 Rev A
4. Handle the ionizing module with care. The ion emitters are sharp pins that
present a puncture hazard.
5. Dirt and debris may be brushed or vacuumed from the ionizing module, or the
ionizing module may be replaced.
6. To install the ionizing module, line the Point Cleaner hole with the point
cleaner button and insert module into unit.
7. Secure the ionizer module with the (4) screws at the corners of ionized air outlet.
8. Press Point Cleaner button and make sure it returns freely to check for proper
operation of the point cleaner.
Ion Balance
1. A closed-loop electronic balancing circuit in the blower controls the output
ration of negative to positive ions. The circuit is preset at the factory and
normally requires no further adjustment.
2. Balance may be evaluated using a charged plate monitor such as the Simco-Ion
CPM. The plate should be placed at the typical operating distance for testing
and adjustment. Static charges in the vicinity of measurement will affect
reading, remove or neutralize static charges in the vicinity before taking ion
balance measurements.
3. The balance adjustment potentiometer is accessible through a small opening on
the face label of the Fantom. Using a flat-blade screwdriver, carefully adjust the
potentiometer until the charged plate monitor indicates “zero”.