4
Chargemaster Pinner Superbar
5101167 Rev. F
4. INSTALLATION
CAUTION –
Fire Hazard
Do not install or operate equipment in close proximity to any flammable solvents
or flammable materials.
CAUTION –
Fire Hazard
Do not exceed 30 kV supply voltage.
Determine Superbar Location
1.
Charging Bar with Grounded Surface
– In Figure 1, the charging bar faces a
production fixture that moves beneath the charging bar (alternatively the bar could
move over the fixture). After the materials to be pinned together are positioned on the
fixture, it moves beneath the charging bar. The negative ions created by the bar are
driven toward the grounded metal fixture by an electric field formed between them.
The top material blocks ion travel through the field and becomes electrostatically
charged, resulting in adhesion between the two materials and the fixture. This
arrangement emulates an interleaving application where paper or film is pinned to
metal prior to cutting and stacking.
Pinner Superbar (-)
1.5" Min.
Figure 1