8
Chargemaster Pinner Superbar
5101167 Rev. F
4. Secure the mounting rods to the insulating support frame using 1/4” fasteners
provided.
5. Set the height, if necessary, by cutting the end of each mounting rod (see Figure-5).
Assure that the bar is parallel to the target material surface.
6. Tighten all nuts with a wrench after verifying the position and spacing between bars
and ground references. Refer to Figures 1-4 for minimum recommended spacing.
Figure 5
Install High Voltage Cables
CAUTION –
Electrical Shock Hazard
Ground all surrounding metal parts in the vicinity of the charging bar.
CAUTION –
Fire Hazard
Do not install or operate equipment in close proximity to any flammable solvents
or flammable materials.
1. Route the high voltage cable for each charging bar along the machine frame or wall
to the power supply. Assure the cable is safely away from all moving parts and sharp
edges.
2. Verify that the high voltage cables are run separately from any control cables
associated with other electronic equipment. The EMI from high voltage cables may
interfere with the operation of sensitive electronic equipment.
3. Assure that the power supply is de-energized and turned off.