6.4.11 Disassemble the rotating assembly
122
124
101
100
356A
125
130
351C
351
125
184
353
425
Figure 56: Head removal
1.
Loosen and remove the head to case nuts (425).
2.
Use the jackscrews provided with the pump in order to loosen the head (184) from the casing (100).
WARNING:
Risk of severe physical injury or death from explosion of trapped liquid. Never use heat to re-
move parts unless explicitly stated in this manual.
3.
Push the shaft assembly towards the radial end until it stops. Maintain this position until the next
step is completed.
4.
Insert eyebolts (not supplied) in the pre-drilled threaded holes in the top outside perimeter of the
head.
WARNING:
Use the eyebolts to lift only the head. They will not support the weight of the entire pump.
5.
Slide the head out of the pump without the rotor.
6.
Remove the head (184) from the casing (100) to the work area.
7.
Use a sling in order to pull the shaft out of the pump only as far as the radial end is still supported
by the radial end throat bushing (125).
CAUTION:
Support the thrust end of the shaft before you position the slings to remove the rotor.
6.4 Disassembly
80
3620 i-FRAME API type BB2 single stage / ISO 13709 2nd Ed/API 11th Ed Installation, Operation, and Maintenance