WARNING:
The pump may handle hazardous and/or toxic liquids. Trapped or undrained liquid can cause
explosions when heat is applied. Never apply heat at the pump site for this reason. Heat can
also distort machined surfaces.
19. If applicable - Remove bearing spacer (443V).
20. Remove the inboard labyrinth seals (333A) and oil ring (114).
6.4.8 Disassemble the radial end (sleeve/tilt pumps)
Figure 50: Radial end (sleeve/tilt) disassembly
1.
Remove all instrumentation from the upper and lower half bearing housing (134). Plug any open
connections.
2.
Remove oil feed piping from the lower half bearing housing (134).
3.
Remove drain piping from the lower half bearing housing (134)
4.
Remove the two taper pins between the upper and lower half of the bearing housing (134).
5.
Remove the hex cap screws that connect the upper and lower half of the bearing housing (134).
6.
Tighten the two jack bolts on the horizontal parting flanges of the bearing housing (134) in order to
separate the two halves.
7.
Remove the top half of the bearing housing (134).
6.4 Disassembly
3620 i-FRAME API type BB2 single stage / ISO 13709 2nd Ed/API 11th Ed Installation, Operation, and Maintenance
Manual