Figure 55: Thrust dowel pin removal
24. Loosen and remove the nuts (427J) that hold the bearing housing (134A) in place.
25. Rotate the lower half of the sleeve bearing (117) around the shaft (122) in order to remove the bear-
ing from the lower housing.
26. Remove the lower half of the bearing housing (134A).
27. Remove the thrust collar nut (283) to remove the thrust collar, thrust collar key (282), and bearing
spacer (443V).
28. Remove the inboard labyrinth seal (333A).
6.4.10 Guidelines for i-ALERT
®
2 Equipment Health Monitor disposal
Precautions
WARNING:
•
Explosive hazard and risk of personal injury. Heating to high temperatures could cause
combustion of the condition monitor. Never heat the condition monitor to temperatures in
excess of 149°C | 300°F or dispose of in a fire.
Guidelines
This product contains Lithium Thionyl Chloride. Contact your local waste management companies to pro-
vide assistance in the disposal of the device that contain this type of battery.
6.4 Disassembly
3620 i-FRAME API type BB2 single stage / ISO 13709 2nd Ed/API 11th Ed Installation, Operation, and Maintenance
Manual