3

in the area a bolt-on or child-proof cover is 

recommended.

3. PIPINg
3.1.

 Discharge pipe should be the same size 

as the pump discharge to insure optimum 

performance. Using undersized pipe may 

dramatically reduce the flow and therefore 

waste energy. Your pump supplier can sug-

gest the correct pipe for your installation.

3.2.

 Install a threaded pipe adapter, matched 

to the pipe type you are using, into the 

threaded pump discharge. One end will have 

a male thread and the other end will have 

a barbed connector, compression fitting or 

solvent weld connector. Use Teflon

®

 tape on 

all threaded joints. If using solvent welded 

pipe and fittings it is best to dry fit them first 

and after verifying the fit, solvent weld. A 

union installed just above the sump or basin 

cover will facilitate future maintenance and 

replacement. 

See Chart 1 for discharge sizes

.

3.3.

 Install a line check valve within  feet of 

the pump. Install per valve manufacturer’s 

instructions.

IMPORTANT -

 Drill a 

1

8

" (3.mm) relief hole 

in the discharge line approximately ” (51 

mm) above the pump discharge connection 

but below the check valve and within the 

sump. This “relief ” hole allows trapped air 

to escape from the pump and prevents air-

locking the pump. Failure to drill this hole 

is a major cause of sump pumps failing to 

pump after long periods of inactivity such as 

seasonal use. Model ST is self-venting - no 

hole is required.

4. INSTALLATION IN SUMP
4.1.

 The pump can be placed directly on the 

bottom of a poly or fiberglass sump basin 

or a concrete sump bottom. If the bottom is 

packed gravel the stones must be larger than 

½” (13mm) in diameter and the pump 

should be placed on bricks for support.

4.2.

 After connecting the discharge pipe to the 

pump it can be lowered into the sump (ba-

sin). Always lower the pump by the handle 

and the pipe, never by the power cord. Place 

the pump against the basin wall so the switch 

is to the center. 

See "Installation Data"

.

3. PIPINg

4. INSTALLATION IN SUMP

1. gENERAL INFORMATION
1.1.

 Sump pumps are designed to operate inter-

mittently and usually seasonally. It is recom-

mended that you test the pump before your 

rainy season begins to insure that the pump 

and switch are operating properly.

1.2.

 We suggest installing a high water alarm 

system and a battery back-up pump system 

for finished basements or areas where flood-

ing will cause property damage. A back-up 

generator is another option you can discuss 

with your pump installer. Most power out-

ages occur during rain storms, just when 

you need your sump pump the most! Pump 

manufacturer's warranties cover only the 

pump. Labor and incidental damage such as 

flooding is not covered.

2. PRE-INSTALLATION CHECKS
2.1.

 Open all cartons and inspect for shipping 

damage. Report any damage to your supplier 

immediately.

2.2.

 Verify that all equipment is the correct volt-

age. Warranty does not cover damage caused 

by connecting pumps and controls to incor-

rect voltage.

2.3.

 Is your basin sized correctly and the proper 

type for the location?

Diameter

 - It must be wide enough to allow 

the pump and switch to physically fit and 

provide room for the switch to operate 

freely. The vertical switch models typically 

require less diameter than the wide-angle 

float models. 

See "min. basin diameter" in 

Chart 1

.

Depth

 - It must be deeper 

than the minimum depth at 

which the switch turns the pump On. As an 

example, if the pump turns on at 15" you 

want to use a basin deeper than 15”. 

 

See "On level" in Chart 1

.

Style

 - There are several 

sump basin styles available. 

The location of the sump determines if you 

require a cover and what type you require. 

It is important to keep debris from entering 

the sump and clogging the pump. An open 

sump in a traffic area such as a basement is 

dangerous. If children or pets will be playing 

2. PRE-INSTALLATION CHECKS

1. gENERAL INFORMATION

WARNING

CAUTION

Содержание Goulds Pump SP02

Страница 1: ...onstruction Stainless Steel motor casing and fasteners Glass filled thermoplastic impeller and casing Bearings Upper and lower heavy duty ball bearing construction Motor is permanently lubricated for...

Страница 2: ...three prong grounding plug 115V AGENCY LISTINGS APPLICATIONS Specially designed for the following uses Basement draining Water transfer Dewatering SPECIFICATIONS Pump Discharge size SP024 11 4 NPT SP...

Страница 3: ...m Float Switch Cord Discharge Min Min Minimum Maximum Shipping Order No HP Volts Amps Circuit Phase Style Length Connection On Off Basin Solids Weight Breaker Level Level Diameter Size lbs kg SP024V 1...

Страница 4: ...d the ITT Engineered Blocks Symbol are registered trademarks and tradenames of ITT Corporation SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE BSP02 03 August 2006 2006 ITT Corporation Engineered...

Страница 5: ...lds Pumps Sump Pumps Installation Operation and Maintainence Instructions Goulds Pumps is a brand of ITT Water Technology Inc a subsidiary of ITT Industries Inc www goulds com Engineered for life Wast...

Страница 6: ...rformed by a qualified technician Always follow the National Electrical Code NEC or the Canadian Electrical Code as well as all local state and provincial codes The pump must be connected to a dedicat...

Страница 7: ...never by the power cord Place the pump against the basin wall so the switch is to the center See Installation Data 3 Piping 4 INSTALLATION IN SUMP 1 GENERAL INFORMATION 1 1 Sump pumps are designed to...

Страница 8: ...debris children or pets falling into the basin See Basin Style in Section 2 3 6 SEASONAL SERVICE MAINTENANCE 6 1 If your sump pump only operates seasonally and then sits idle for months it is recom 5...

Страница 9: ...Vertical Switch 12 8 5 2 No Switch Manual Manual 9 115 7 1 LSP07 10 1 20 1 Wide Angle Switch 12 5 6 5 12 3 8 15 6 8 230 3 5 SP024 2 4 1 SP025 10 1 Vertical Switch 10 6 3 9 3 8 SP035 1 3 115 3 0 1 8 3...

Страница 10: ...Figure 6 Pumpmaster and Pumpmaster Plus Hard Wired Figure 4 Tether length INSTALLATION DATA INSTALLATION DATA Typical Pump Installation in Sump Figure 3 PUMP ELECTRICAL PLUG CHECK VALVE PIGGYBACK SWI...

Страница 11: ...mages of any kind and e Reimbursement for loss caused by interruption of service For purposes of this warranty the following terms have these definitions 1 Distributor means any individual partnership...

Страница 12: ...umps Bombas para sumideros Manual de Instalaci n y Operaci n Goulds Pumps son una marca de f brica de ITT Water Technology Inc un subsidiario de ITT Industries inc www goulds com Engineered for life A...

Страница 13: ...mpre siga el C digo El ctrico de EE UU NEC o el C digo El ctrico Canadiense adem s de todos los c digos locales estatales y provinciales La bomba debe conectarse a un circuito el ctrico dedicado prote...

Страница 14: ...que la bomba se bloquee con aire La no perforaci n de este orificio es una de las 3 TUBER AS 1 INFORMACI N GENERAL 1 1 Las bombas para sumidero est n dise adas para funcionar intermitentemente y habit...

Страница 15: ...na salida de corriente dedicada Luego conecte el enchufe macho est ndar de la bomba a la parte trasera lado hembra del enchufe de los interruptores en t ndem 4 6 Afiance los cables de alimentaci n a l...

Страница 16: ...as 4 Motor defectuoso 5 Bloqueo con aire 6 Baja tensi n 7 Carga del sistema demasiado alta 8 Bomba obstruida 9 Control de nivel defectuoso o interruptor situado incorrectamente 10 Direcci n incorrecta...

Страница 17: ...vertical 12 8 5 2 Sin interr Manual Manual 9 115 7 1 LSP07 10 1 20 1 Interr de 12 5 6 5 12 3 8 15 6 8 230 3 5 ngulo ancho SP024 2 4 1 SP025 10 1 Interr vertical 10 6 3 9 3 8 SP035 1 3 115 3 0 1 8 3 6...

Страница 18: ...l sumidero Figura 3 ENCHUFE EL CTRICO DE LA BOMBA V LVULA DE RETENCI N ENCHUFE DE INTERR EN T NDEM RECEPT CULO DE PARED CONECTADO A TIERRA INTERRUPTOR DE FLOTADOR UNI N ORIFI CIO DE ALIVIO DE 1 8 PULG...

Страница 19: ...emergentes de cualquier naturaleza y e el reembolso de cualquier p rdida causada por la interrupci n del servicio A los fines de esta garant a los t rminos Distribuidor Comerciante y Cliente se define...

Страница 20: ...T Goulds Pumps Pompes de puisard Manuel d installation et d utilisation Goulds Pumps est une marque d ITT Water Technology Inc une filiale d ITT Industries Inc www goulds com Engineered for life Eaux...

Страница 21: ...cien qualifi Il faut toujours suivre les pres criptions du code provincial ou national de l lectricit On doit brancher la pompe un circuit lectrique ind pendant prot g par un disjoncteur ou des fusibl...

Страница 22: ...es d arr t saisonni res Mod le ST est art de l auto portrait venting aucun trou n est exig 3 TUYAUTERIE 1 INFORMATIONS G N RALES 1 1 Les pompes de puisard sont con ues pour un usage intermittent g n r...

Страница 23: ...le courant au panneau de disjonc teurs ou au sectionneur ou aux deux si c est le cas 5 2 Remplir le puisard ou la cuve d eau et noter le niveau de l eau quand la pompe d marrage et arr te La pompe de...

Страница 24: ...ans ARR T DE LA POMPE V causes probables 7 8 9 10 et 13 R P TITION SANS ARR T DU CYCLE DE FONCTIONNEMENT V causes probables 9 11 12 et 13 CAUSES PROBABLES 1 Protecteur thermique d clench 2 Disjoncteur...

Страница 25: ...LSP07 10 1 d placem 20 1 angul 12 5 6 5 12 3 8 15 6 8 230 3 5 SP024 2 4 1 SP025 10 1 Vertical 10 6 3 9 3 8 SP035 1 3 115 3 0 1 8 3 6 Aucun contacteur Manuel Manuel SP28C 115 75 W 10 1 Autocommande pa...

Страница 26: ...HE DE LA POMPE CLAPET DE NON RETOUR FICHE PRISE DU CONTACTEUR PRISE MURALE MISE LA TERRE RACCORD UNION TROU PUR GEUR D AIR DE 1 8 po PLAGE DE POMPAGE DONN ES SUR L INSTALLATION DONN ES SUR L INSTALLAT...

Страница 27: ...23 NOTES NOTAS NOTES NOTAS...

Страница 28: ...les pertes d coulant de la panne Aux fins de la pr sente garantie les termes ci dessous sont d finis comme suit 1 Distributeur signifie une personne une soci t de personnes une soci t de capitaux une...

Отзывы: