For normal activation, connect the pit module to the water meter register. The water module
polls for a register every hour. The OpenWay Riva pit module automatically activates after it
detects the register.
Note
: Do not program configuration changes to the Riva water module until it is connected
to the water meter register.
Caution
:
• The FC200SR, FC300SR, 900 MHz Belt Clip Radio, or Itron Mobile Radio are
the only devices that support progamming for the OpenWay Riva pit module.
• Keep a minimum of 12 inches between the Riva pit water module and
programming device while programming configuration changes are completed.
• Do not place the programming device antenna directly on the pit module.
Extending the water pit module cable
Order the 25-foot inline connector extension cable assembly (CFG-0151-401) to extend the
cable of the pit module.
Connecting the pit module to an encoder-type meter
register
Connect the pit module cable to the encoder-type register using the wire connections in the
following table.
Pit module wire color
Red
(data)
Black
(power/clock)
White
(ground)
Register manufacturer
Register screw terminal
Badger ADE, E Series,
HR E LCD, HR E
Mechanical
Green
Red
Black
Badger M5000 Mag
Meter
Green Terminal: Out
4+
Red Terminal: Input + Black Terminal: Input
- and Out 4-
Elster AMCO InVision,
Scancoder, AquaMaster,
AquaMaster III
Red
Green
Black
Elster AMCO SM 700
(Severn Trent), Q200
(Sensus Protocol)
Green
Red
Black
Elster AMCO evoQ4
Mag, evoQ4 (Sensus
Protocol)
Red
White
Black
Itron (Actaris) Cyble
Coder
Green
Red
Black
Initializing, Connecting, and Programming the OpenWay Riva Water Pit Module
OpenWay Riva Pit Water Module Installation Guide TDC-1666-000
10