• Last Good Read and Extended Tamper Flags may be set when a register is not
connected.
• If the pit module reads a connected register, the pit module automatically moves to
Run Mode.
2. Run mode
• Pit Module normal operation mode.
• The OpenWay Riva Water Pit Module transmitted message is dependent on its factory
settings or setting programmed with FDM for standard consumption messages (SCM
+).For SCM+ (Mobile), the pit module default bubble-up rate is 10 seconds.
3. Meter manufacturer quiet mode
• Meter manufacturers can configure the pit module for Quiet Mode after initializing and
direct mounting the pit module in the factory.
• The pit module awakens from Quiet Mode and enters run mode in one of two ways:
1. The pit module detects consumption at the top of the hour (last hourly interval >1 or
<-1).
2. The pit module receives a two-way command (for example, a
Read ERT
using FDM
software).
Error/warning flags
For OpenWay Riva modules reporting in ChoiceConnect 100S mode.
Register error detected. Register error detected indicates that the pit module is not
communicating with the register/meter. The tamper flag automatically clears after the pit
module receives a successful read from the register.
Note
: The register error detected flag may be an indicator of a damaged register.
Register error flag
• The register error flag sets if the register error detected flag is active for 24 hours.
• The register error flag remains active for 40 days in mobile mode.
Extended tamper flag (retrievable with two-way communication).
Low battery warning. The pit modules include a battery life estimator. The estimator is based
on the number of data packets sent at the various power levels and the age (self-discharge)
of the pit module. The low battery warning allows the utility to easily identify which water
modules are nearing end-of-life in a mixed population and gives the utility the opportunity to
schedule replacement.
Note
: The low battery warning is a single flag that is set when the battery has less than 10%
remaining capacity, which typically corresponds to 2 years of battery life remaining. Battery
life is evaluated daily at midnight.
For OpenWay Riva modules operating in OpenWay Riva Network mode.
About the OpenWay Riva Water Module
OpenWay Riva Pit Water Module Installation Guide TDC-1666-000
7
Proprietary and Confidential