Section 9
PEAK VOLTAGE
MULTI-STRIKE IGNITION SYSTEMS MUST BE
OPERATED IN SINGLE STRIKE MODE
WHEN TESTING WITH THE ACCUTEK III.
NOTE: For the following tests, the “PUSH TO TEST”
switch is not depressed - (OFF)
This feature will display the primary peak voltage level generated by the
ignition source being tested. When testing ignition system peak voltage, the
test can be performed at the shutdown lead, ignition coil, primary wiring
terminal strip etc.
9.1
Place the TEST switch to the COIL/IGN position and the
MEASUREMENT switch to PEAK VOLTS.
9.2
While observing polarity, connect the leads from the HV-
TEST to the shutdown lead of the ignition system. The
ACCUTEK III will now be displaying the primary peak out-
put level being delivered from the ignition source. If it is safe
to do so, disconnect all devices connected to the shutdown
lead. If the measured primary voltage rises from the previous
reading, this could indicate excessive load on the ignition
source by one or more of the devices or instruments connect-
ed to the shutdown lead.