• Connect the ignition coil to the multi-meter/ohmmeter using the
appropriate cables and switch positions (refer to the manufacturer’s
operators manual for further instructions). The meter will now dis-
play the measured resistance. These results can be compared to
manufacturer’s data (section 15) to determine if the coil is within
specs.
VERY IMPORTANT, PLEASE READ CAREFULLY
The information below deals with negative ground systems. Always
observe ignition coil polarity before connecting the ACCUTEK III to
ignition coils.
4.2 Firing Unshielded ignition coils
Note:
A shock hazard exists if the following procedure is not
followed carefully.
4.21
All tests must be performed in a nonhazardous area and on an
electrically conductive surface.
4.22
A lead from the ACCUTEK III “COMMON” output, igni-
tion coil negative, and one side of the spark gap, must be con-
nected to the conductive surface - this will ensure that the
spark energy will be able to return to the tester.