Console user manual
26
01 - 10 - 2004
222
Internal error 12
223
Movement interrupted by coherence sensors (rapiers in shed when shed closed)
231
Coupling not released before engaging
232
Requested staggering not accepted (out of range +/ 30°)
233
Switch loom off and then back on again and then repeat reset procedure
234
PZPT sensor not found before coupling
235
Dobby check sensor not found before coupling; the reason could be a faulty dobby
check sensor. Follow this procedure:
- switch the loom off and then back on again
- bypass the reset procedure (see parag A.6).
- jog the loom a few degrees in slow motion to engage the coupling
- manually synchronise the shafts (see parag. A.8).
- make two complete turns in slow motion: the appropriate alarm will indicate if a
sensor is faulty
- find the fault (sensor, gaps between flags and sensors, wiring, connectors, etc.)
236
More than 4.28° covered without coupling
237
Coupling movement timeout (3.0 sec)
238
Staggering after coupling cannot be established
239
Incorrect staggering after coupling
240
Internal error 240
241
Internal error 241