Console user manual
22
01 - 10 - 2004
13367
No Driver OK signal from drive: problems with the drive or with the drive/loom
connections.
13368
Enabling relay KD2 open during tracking
13369
Enabling signal not active during tracking
13370
No IGBT repetition signal from drive: problems with the drive or with the drive/loom
connections.
13371
Speed too high when not weaving
13372
RH restart light flashing error
13373
LH restart light flashing error
13374
Loom width not correct, set-up setting error
13375
Loom width not correct, cabling error
13376
Hi Drive device alarm: Drive outputs short-circuited (internal code 1)
13377
Hi Drive device alarm: Motor thermal (internal code 2)
13378
Hi Drive device alarm: motor resolver disconnected (internal code 4)
13379
Hi Drive device alarm: 24 Volt supply error within drive (internal code 8)
13380
Hi Drive device alarm: Overvoltage (internal code 16)
13381
Hi Drive device alarm: Drive dissipator temperature (internal code 32)
13382
Hi Drive device alarm: Motor short-circuited (internal code 64)
13383
Hi Drive device alarm: Drive overvoltage (internal code 128)
13384
Hi Drive device alarm: Error during preloading (internal code 256)
13385
Hi Drive device alarm: Error during braking recovery (internal code 512)
13386
Hi Drive device alarm: Control supply voltage too low (internal code 1024)
13387
Hi Drive device alarm: Speed tracking error (internal code 2048)
13388
Hi Drive device alarm: Undervoltage (internal code 4096)
13389
Hi Drive device alarm: Speed limitation during tracking (internal code 8192)
13390
Hi Drive device alarm: Incorrect E2prom (internal code 16384)
13391
Hi Drive device alarm: Generic alarm
13392
Oil pump motor temperature too high
13393
Drive switched off because handwheel has been used for manual movements;
press slow motion button to reset drive and then wait for the orange lamp to stop
flashing
13394
Main motor temperature probe disconnected
13395
Incoherent status of relays on board JHD (check: JHD, HDI, JHD power supply)
13396
Incoherent enabling status, check JHD and HDI
13397
Incorrect repetition signal for drive IGBT relay; check drive and drive/loom cabling
13398
Wrong oil pump motor temperature: check cabling of NTC probe on oil pump