Down-Level: Trigger lower limit value.
•
Current trigger
When the DC terminals detect that the current reaches the trigger current
setting value and is within the range of the upper and lower trigger limits, a
data recording operation is triggered.
–
Level: Trigger threshold.
–
Up-Level: Trigger upper limit value.
–
Down-Level: Trigger lower limit value.
•
External
Connect to pin 4 of the digital I/O interface (P-IO) and set pin 4 to
Ext-Trig
→
-
Trig-In
→
Dlog
to trigger.
For details, see
6.11.4 IO–4. Ext-Trig, Not-Invert
After the data recording function is started, the recorded data is saved in USB
memory device in .csv format. The user can get access to these files for analy-
sis based on needs.
6.5 Set the Beeper Status (Beep)
The user can turn the instrument beeper sound on or off base on personal
requirement.
The beeper sound works in the following scenarios:
•
A beeper sound produced when the front panel key is pressed.
•
When an error is generated inside the instrument, such as when the instru-
ment receives an unprocessable command in the remote state. At this time,
the instrument produces a beeper sound, and the flag “Error” appears on the
VFD.
•
When the instrument is under protection status, such as over-temperature
protection. At this time, the instrument produces the beeper sound.
The setting procedures are as follows:
1. Press the composite keys
[Shift]+[P-set]
(System) on the front panel to en-
ter the system menu.
The first displayed menu item
Beep
is used to set the beeper status.
2. Press
[Enter]
key to enter the parameter setting interface.
3. Press the Left / Right key or turn the knob to adjust the value of this
parameter.
Copyright © Itech Electronic Co., Ltd.
175
Содержание IT6000B Series
Страница 130: ...Power Supply Function E 02 The waveform is as follows Copyright Itech Electronic Co Ltd 118...
Страница 132: ...Power Supply Function E 06A The waveform is as follows Copyright Itech Electronic Co Ltd 120...
Страница 136: ...Power Supply Function E 16 The waveform is as follows Copyright Itech Electronic Co Ltd 124...
Страница 137: ...Power Supply Function E 18 The waveform is as follows Copyright Itech Electronic Co Ltd 125...
Страница 141: ...Power Supply Function The waveform of upper range is as follows Copyright Itech Electronic Co Ltd 129...
Страница 150: ...Power Supply Function Copyright Itech Electronic Co Ltd 138...