Ubmin
Holding
Time
Voltage holding time at
Ubmin
E-08
Slow decrease, quick increase of the sup-
ply voltage test waveform
Ubmax
Start voltage
Ubmin
Holding voltage
Ubmin
Holding
Time
Voltage holding time at
Ubmin
E-09
Reset behavior test waveform
Ubmin
Holding voltage
E-11
Start pulses
Cold-Start
Cold start
Normal
Standard experi-
mental pulse
Severe
Enhanced experi-
mental pulse
Warm-Start
Warm start
E-12
Voltage curve with intelligent generator
control
U
Voltage drop between DUT
and battery terminals
E-02 Transient Overvoltage Pulse
Transient overvoltages may occur in the electric system due to the switching off
of loads and due to short accelerator tip-ins. These overvoltages are simulated
by means of this test. This test may be used for the electrical life test. The test
pulse of E-02 Transient overvoltage is shown in the figure below: