Three digit display under the symbol
Normally, it displays the temperature of the hot water on boiler's outlet. When the boiler
is in stand-by mode, it displays
.
During the DHW temperature setting (by pressing the buttons
and
), it shows
the
temperature value changing
; in case of
alarm
it displays the
ID number
of the alarm
(see "Alarms - boiler block" on page 41); during the
setting (reserved to the Techni-
cian)
it displays the
value
of the chosen
parameter
�
RESET
It appears when the boiler is locked or anyway is present an error that the user could man
-
age. See "Alarms - boiler block" on page 41 to identify the problem and the relevant
actions to be carried out.
SERVICE
It appears when the boiler has detected an error (mainly a fault) that has to be managed
by the Technician. The User can anyway see "Alarms - boiler block" on page 41 to get
information about and the eventual actions to be carried out.
It informs that the outdoor probe (accessories) is installed.
Note:
In
this case the CH system temperature is automatically set and so the
use of but-
tons
and
is different from the standard way: for deeper detail
s rely on
kit
instruction and see "Outdoor Sensor Kit" on page 52.
Commands on the lower side
1
System pressure gauge
2
System filling and pressure restoring cock
3
GAS cock
Commands outside the boiler
Externally the boiler, suitably positioned in the build
-
ing (generally by the installer or by the electrician), two
devices that the user should access to, are present. The
presence and the characteristics of these devices are pre
-
scribed by the regulation in force.
Two-pole switch:
it is located usually close to the boiler and it's for electrically insulating the boiler
itself from the domestic mains power supply network. It is useful to disconnect the boiler from the
electrical supply, e.g. during inactivity periods (see "Safety shut off" on page 11) or in some cases
of alarm (see "Alarms - boiler block" on page 41).
Room thermostat:
it commands electrically the boiler to activate or deactivate the heating system, in
order to keep the room temperature (detected by a sensor) within a value set by the user, Regula
-
tion in force prescribe its positioning, the temperature limits within the user can adjust it and the
periods of heating.
Remark:
an optional, original Remote Control kit is available (see "Remote Control Kit" on page 53
for information) or a cutting-edge chronotermostat kit featuring weekly programming of various
temperature levels and other special functions. Also
wireless
and
GSM controlled
versions are
available.
00315_0
0
2
3
1