Domestic water supply characteristics
The cold water inlet pressure must be lower than 6 Bar.
Besides, for an optimal boiler functioning, wa
-
ter pressure
should be more than 1 Bar
. A lower pressure could make difficult to restore correctly the
pressure the heating system, and reduce the flow of hot water available from the boiler.
In case of higher pressure
it is indispensable to install a PRESSURE REDUCER
upstream the
boiler�
The cleaning frequency of the DHW heat exchanger depends on the water supply hardness.
If the wa-
ter hardness is more than 25° fr it’s required to install a softener to bring the hardness below that value.
Besides, the presence of solid residuals or impurities in the water (for example in case of new systems)
could compromise the correct functioning of the boiler. For DHW production systems, the regulation in
force prescribes a safety filter to protect the systems.
The condensing burner/exchanger assembly requires
particular characteristics for the heating
system liquid
, more restrictive than the ones of the inlet domestic water. See the "Heating" sec
-
tion of the table "Technical data" on page 47.
Protection against freezing
Thanks to its antifreeze system, inner components could never reach a temperature lower than 5°C. This
system is activated when the boiler is supplied by the electrical and gas lines, provided that the pressure
in the heating system is correct.
If some part(s) of the system external to the boiler could be subject to freezing risk, it is advis
-
able to fill the heating circuit with, instead of water, an antifreeze liquid specific for heating
systems, propylenic glycol based, following the instructions of its manufacturer. Pay attention
to the correct product concentration: adding those substances to the heating water in incorrect
dose could lead to the deformation of the seals and cause unusual noises during operation.
ITALTHERM S.r.l. will not be held responsible for consequent damages.
Instruct the User about the antifreeze function of the boiler and about the antifreeze product
added in the heating system.
Outdoor installation in a partially protected place
This type of forced draught condensing boiler can
be installed outdoor, but only in partially protect
-
ed places�
The boiler minimum and maximum working tem
-
peratures are mentioned in the paragraph "Tech
-
nical data" on page 47 and on the boiler data
plate�
The materials used
for the boiler installation,
including the devices and/or the materials used
for thermal insulation, should be so to
maintain
their functionality
within the temperature range
indicated on the data plate�
If the place
where the boiler is located is converted
from outdoor to indoor
(e.g. veranda) it will
be necessary to
verify the compliance
of the new configuration with the laws and rules in force,
and to make the modifications required.