Green Heating Technology
32
Main boiler parameters (PC)
The parameters listed in the following table are limited to those described in this handbook� The com-
plete parameter list is available in the documentation for the technician.
Param-
eter
Adj. range
(fact. set.)
and values
Description
01
0…2
(0)
Type of GAS supply
0
for
Natural Gas (G20)
supply
1
for
Commercial Propane (G31)
supply
2
Do not use this setting
To change the type of gas supply, it is necessary to follow the complete instructions
described in the paragraph "Gas conversion" on page 39.
02
0; 1
(0)
Heating flow temperature setting range
0
Normal
setting, suitable for plants with radiators. This allows the user to
adjust the system flow temperature, by acting on buttons
and
,
within the high-temperature range
1
Reduced
setting, suitable for low temperature plants. This allows the user to
adjust the system flow temperature, by acting on buttons
and
,
within the low-temperature range.
Remark:
in case of mixed plants (with high and low temperature) thanks to optional kit,
set low range
(value 1)
(please also refer to documentation provided with the kit).
03
—
It indicates the CH boiler power during the soft ignition phase.
We recom-
mend to leave the factory setting unchanged.
04
0…99
(*)
It indicates the CH boiler power according to the maximum nominal boiler
power�
Remark
(*): The factory setting depends on the model: see "Power adjustment ta
-
bles" on page 36.
See details in "Max heating power adjustment" on page 37.
05
0…2
(0)
Pump functioning mode during heating working
0
intermittent
for normal applications
(with eventual delay defined by parameter 06)
1
always on
(to fit the needs of particular plants)
2
always off
(use only when external pumps are foreseen).
Remark: The pump will be anyway activated in all other circumstances, e.g. during the DHW
functioning or for anti-freezing or anti-lockout functions.
06
0…15
(3)
Value in minutes. Delay of boiler re-ignition after set Central Heating tem
-
perature has been reached.
(This parameter works only if par. 05 =