User warnings
Important
In case of gas smell:
1 - do not press electrical switches, use the telephone or other objects that can provoke
sparks;
2 - open immediately the windows and the doors in order to cleanse the room air;
3 - close the gas supply taps;
4 - call a qualified technician.
Do not obstruct the ventilation openings
of the gas boiler room, in order to avoid possible
dangerous situations as the creation of poisonous or explosive mixtures.
First starting up and Use
The first starting up and the maintenance of the boiler must be performed by a professionally
qualified staff (for example the installer or the Service Centres authorized by ITALTHERM)
The latter will check that:
f
the label technical data of the gas boiler correspond to those of the gas available;
f
the main burner regulation is compatible with the gas boiler output;
f
the chimney works correctly, expelling the combustion products;
f
the air supply and the combustion products evacuation work correctly, in accordance with the re
-
quirements in force;
f
the conditions for a correct ventilation are guaranteed, also when the gas boiler is located inside a
closed space (with suitable caracteristics).
This boiler is designed and prepared to be supplied with Natural Gas G20 (Methane). It can
be set,
just by means of electronic settings, but
always by a qualified technician, to operate
with Commercial Propane G31
. It must never be used with
butane gas G30
(that can be present,
pure or mixed with Propane G31, in the portable gas bottles for cookers).
The User must not touch sealed items nor break the seals. Only specialized technicians and the
official technical service can break the seals of sealed items.
The boiler is fitted with safety devices that block operation the case of problems with the boiler
or related systems. These devices must never be disabled: if a device intervenes frequently,
have a qualified technician located the cause, even in systems to which the boiler is connected,
and in the flue intake/outlet system that must be efficient and made according to the laws in
force (see examples in paragraph "Flue systems" on page 21). If a boiler component has failed,
you must only use original replacement parts
When the boiler is off for a long period see the Paragraph "Boiler inactivity" on page 11 for
the necessary precautions about the electrical supply, the gas supply and the protection against
freezing.
Do not touch the heated surfaces
of the boiler, as the doors, the flue, the chimney pipe, etc.,
also after the boiler operation because, for a certain time, these surfaces are overheated.
Any
contact with them can cause dangerous scalds.
It is then forbidden to let children or inexperi-
enced people be close to the boiler, during its operation.
Содержание 35 K
Страница 54: ...Green Heating Technology 54 Notes ...
Страница 55: ...Green Heating Technology 55 Notes ...