Green Heating Technology
14
0
1
2
3
4
5
6
0
200
400
1000
1200
600
800
1400
1600
00362
B 01
pr
essur
e (m H
2
O)
water flow (l/h)
mod. 30K
speed 3 - 2 of the pump
The graph is referred
to the capacity available
to the system.
0
1
2
3
4
5
6
0
200
400
1000
1200
600
800
1400
1600
00362
C 01
pr
essur
e (m H
2
O)
water flow (l/h)
mod. 35K
speed 3 - 2 of the pump
The graph is referred
to the capacity available
to the system.
Warnings for the installation of optional kits or special systems
Floor heating system
The safety thermostat(s) that protects the floor against overheating (that could damage the
cladding, the structure or the system itself) must be installed on the flow starting end of the
serpentine embedded in the floor itself. It should not installed on the system flow pipe in prox
-
imity of the boiler, otherwise frequent and unjustified boiler locks, caused by its triggering, are
possible�
Specifications for intake air
Air must be withdrawn from places free of pollutant (like fluorine, chlorine, sulfur, ammonia, alkaline or
similar agents). In the event of installation of the boiler in atmospheres with not negligible presence of
aggressive chemical substances (e.g. hairdressing salons, laundries) we recommend to foresee the air
intake from outdoor, choosing the type C installation.