FAULT
CAUSE
REMEDY
Installed nozzles not suitable for
gas used
Fit right nozzles
Control board faulty
Replace
Power supply disconnected /
Check.
The appliance does not start
Incorrect gas pressure
Set correct pressures
Thermostat fails to engage
Adjust the thermostat
Burnt-out fuse
Replace
Control board faulty
Replace
High room temperature
Room thermostat set too high.
Air in gas pipes
Bleed
Incorrect ignition electrode
distance
Reset the correct distance
The appliance fails to start
(appliance not working properly /
blocked)
Nozzles dirty
Clean nozzles
Gas valve closed
Check / Replace:
- Safety thermostat tripped (tang.
fan or faulty thermostat, gas
setting)
- Valve faulty
No signal from pressure switch.
Check/Replace:
- not suitable pipes (diameter, length,
curves, fitting)
- pressure switch (operation/connections)
- small pipes (cleaning)
- centrifugal fan (connection/operation).
Wrong programming of segments
Adjust the segments.
The timer does not engage or
does not work
Wrong function programming
Position on "clock"
Power supply switch OFF.
Reset and re-programme the timer.