22
INSTALLER
Chance B – outside tube assemblage
This solution can be adapted when the exhaust fume
tubes and the comburent air intake tubes are to the
outside.
Before you wall up the tubes, provide to the
insulate the exhaust fume tubes, with strong
materials resistant at a 200°C temperature (ex.
HT/-Armaflex).
Maintain a distance of MIN 200 mm between
the two end pieces.
- Group adapter connection tubes
- Insert in the wall the assembled group, adapter
connection tubes.
- Fasten the group, adapter connection to the tem-
plate with the furnished screws.
Complete the installation, assembling it with the rest of
the tubes, fastening them to the wall with commercial
clamps.
Chimneypot assemblage
To assemble the chimneypot on the unloaded intake
tubes use the clamp (1) and the (2) safety screw.
The chimneypot application has to satisfy the fol-
lowing requirement.
-The top of the exhaust fume tube has to be out of
the ebb zone, to avoid the eventual pressures that
will prevent the free exhaust product of the combu-
stion in the atmosphere.
-The chimneypot has to be placed right on top of the
tube in the proper way, if it’s not placed in the proper
way, the fumes will get inside the tubes, and if this
happen it will cause problems to the appliance.
B
MIN
200
mm
2
1