Italkero Fiammella Скачать руководство пользователя страница 27

After performing all the preparation operations for ini-
tial start-up, to start the appliance:

- make sure the fuel tap is open;

- fit the plug in the socket on the appliance;

- move the master switch (if fitted) to "on" or fit the
power plug in the wall socket;

- press the On/Off key (see User section, key 3) to
switch on the appliance;

- set the room thermostat  at a high value to reduce
heating time;

- set the heating power and the desired fan speed;

- set timer function on “manual” mode.

After startup, the appliance runs until it reaches the
set room temperature (operation signal on the
display goes off).

In case of malfunctions in startup procedure or ope-
ration, the appliance STOPS and the relevant
unblock signal lights up on the display. Reset the
appliance by keeping the unblock button pressed.
Wait until the startup procedure is completed and the
operation signal lights up.

- When the appliance is running, set the clock and
the timer for automatic operation (see User section).

2

1

OK

2

1

2

1

OK

TIMER NO

2

1

FIRST SERVICE START

27

CUSTOMER SERVICE

Содержание Fiammella

Страница 1: ......

Страница 2: ...COMPLIANCE Our appliance are compliance at Gas directive 90 396 CEE Electromagnetic directive compatible 89 336 CEE Low tension directive 73 23 CEE 0694 RANGE F i a m m e l l a MODEL CODE F M 4 0 R 2...

Страница 3: ...l be long lasting reliable when it is installed and used properly manufacturer s guidelines are followed Good work and thanks The Manufacturer 3 GENERAL WARRANTY Provided that it is fitted in accordan...

Страница 4: ...ical collegaments pag 25 Gas connection pag 26 CUSTOMER SERVICE Preliminary operations pag 26 First service start pag 27 Processor control box malfunction pag 28 Controls during the first after starti...

Страница 5: ...nt to Art 17 of law no 46 90 and the instructions provided by the Manufacturer in the installer s booklet that accompa nies the product The APPLIANCE must be used as intended by the Manufacturer and f...

Страница 6: ...the apparatus The appliance is a gas radiator that heat up the atmosphere It has an intake of air that goes in the combustion chamber type C The appliance is made with an aluminium body that allows a...

Страница 7: ...tion fan 12 Combustion chamber 13 Pressure switch 14 Battery holder buffer batteries 15 Control unit 16 Combustion fan 17 Ignition electrode 18 Detection electrode 19 Air extraction pipe 20 Digital co...

Страница 8: ...230 50 135 IP20 3 96 3 41 2 9 LPG 28 8 36 4 0 354 0 228 0 62 95 160 17 21 Methane 12 0 0 407 0 285 1 10 95 160 43 7 5 Methane G30 G31 kg h 0 349 0 225 Main pressure nomination mbar 29 37 20 DESCRIPTIO...

Страница 9: ...ional VC COMBUSTION FAN VTC TANGENTIAL CENTRIFUGAL FAN CN CONNECTOR T1 POWER TERMINAL VT TANGENTIAL FAN TA IGNITION TRANSFORMER GND 24V REMOTE CONTROL POWER SUPPLY TX RX SIGNAL TRANSMISSION RETURN BL...

Страница 10: ...enu line d Press SELECT key key 5 note keys 1 2 4 and 5 acquire different functions in the different menus required setting e Press keys 1 and 2 to set the required parameter f Press key 4 to store th...

Страница 11: ...union for 54 mm pipes 4 3 9 mm screws for fastening adapter 4 8 mm screw anchors for fastening template 2 54 mm pipes L 500 mm 1 Single end piece with integrated rosette 4 6 mm screw anchors for fast...

Страница 12: ...L CODE T P 5 4 0 P 0 0 0 0 0 description KIT std EXHAUST INTAKE 54mm 1 INDIVIDUAL T P 5 4 S P 0 0 0 0 0 KIT special EXHAUST INTAKE 54mm 2 SINGLES KIT special EXHAUST INTAKE 54mm 1 INDIVIDUAL INTERNAL...

Страница 13: ...Height B mm 1070 Width C mm 542 Depth A mm 351 Weight kg 43 DESCRIPTION fiammella 13 INSTALLER WEIGHT DIMENSION c b a...

Страница 14: ...k if around the appliance tubes there are mate rials that can support the heath second check if the wall is made of the right material and can support the appliance weight Verified if around the exhau...

Страница 15: ...f more 200 C ex HT Armaflex of temperature Realize the holes for fastening the tubes after establish the hangers length insert it in the right position Before assembling the tubes kit verifying that t...

Страница 16: ...rner and level mark the holes B 8 mm to fasten the template to the two corner walls mark the centre point C on the wall and then make the hole for the extraction and exhaust pipes make a 110 mm hole i...

Страница 17: ...from the out side Insert in the wall the assembled group adapter con nection angles and curves Position the unloaded intake tubes at thread outside wall being real careful that the short tube is alway...

Страница 18: ...dicated when the exhaust fumes and intake are fore way the apparatus The type of installation are more than one kind but they can be lead to the 3 example described in this chapter Before pipes kit as...

Страница 19: ...rs provided Use the holes C CORNER installation rest and fasten the brackets D above the template using the holes C Fasten the Template Brackets to the corner walls using the holes E on the brackets W...

Страница 20: ...le the two flanges 1 unscrew the screws 2 take off the reductions 3 only for the 0 32mm tubes then assemble the group Assemble the unique terminal 4 to tube 5 The cut has to be perpendicular to the ax...

Страница 21: ...er is enough to get throu gh the fastening holes with the bit of 3 mm Group adapter connection tube With 54 mm tubes Assemble the die cast angle curves 6 only for 0 54mm tubes on the adapter connectio...

Страница 22: ...furnished screws Complete the installation assembling it with the rest of the tubes fastening them to the wall with commercial clamps Chimneypot assemblage To assemble the chimneypot on the unloaded...

Страница 23: ...nloaded fumes 3 before assembling the ter minal Approach the apparatus inserting the unloaded intake fumes curves in the right adapter connection tubes To fasten the tubes use grease and be sure that...

Страница 24: ...ol away from the appliance max 2 95 m This standard solution has been conceived to read the best comfort room temperature In this position in fact the remote control senses a temperature at human heig...

Страница 25: ...ket provided and making an EARTH connection that is 2 cm longer than the PHASE and NEUTRAL leads Connect the other end of the cable to a socket or omnipolar switch in conformity with CEI standards con...

Страница 26: ...nt to realize a good ground connection and to respect the neutral phase During the first starting you might verify vapour and irritating smells not dangerous To avoid these discomfort we advice to aer...

Страница 27: ...desired fan speed set timer function on manual mode After startup the appliance runs until it reaches the set room temperature operation signal on the display goes off In case of malfunctions in start...

Страница 28: ...the gas pressures are as under the Table The gas pressure value has to be as in the table The apparatus execute a stop and next restart Operating from the main control panel Operate on the atmospheri...

Страница 29: ...r 5 and disk 8 Unscrew the 3 injectors 6 change them with the new ones Be real careful when you fasten the injec tor check on the injector that it has the right values as in the table The injectors se...

Страница 30: ...as spe cified in the table To make a regulation operate on the screw that is on the modulator body 4 Rotating the regulator screw 3 clockwise the pressure decrease rotating counter clockwise the pres...

Страница 31: ...h to the off position Close the gas tap Wait that the appliance gets cold completely Cover clean The only cleaning that is required by the owner involves removing the cover and wiping it clean the dus...

Страница 32: ...ittle brush with metallic hair for cleaning after insert the electrode group 1 o 2 if necessary exchange the seal gasket 4 be real careful to not damage the electrode Pressure switch tubes Check that...

Страница 33: ...mbustion chamber 6 Disassemble a half sleeve 4 with the clamp 2 and after the fan 5 Unscrew the screw away the fan frame complete of curves connector 7 and ant vibration gasket 8 Disassemble the curve...

Страница 34: ...trips if the convection fan is not working properly or anomalous overheating occurs and or the outflowing air temperature reaches over 107 C disengaging the burner closing the gas valve and stopping...

Страница 35: ...witch from the frame Reassemble the new pressure switch Insert the silicone tubes 3 o 4 also be real careful when you reconnect the cables if you are not sure of what you are doing look at the electri...

Страница 36: ...ures Thermostat fails to engage Adjust the thermostat Burnt out fuse Replace Control board faulty Replace High room temperature Room thermostat set too high Air in gas pipes Bleed Incorrect ignition e...

Страница 37: ...as replace Power of appliance not enough for installation premises Replace the appliance with a more powerful one Faulty control board Replace The tangential fan does not work Faulty motor Replace Fau...

Страница 38: ...Sig Venditore Via tel Sig Installatore Via tel Sig Servizio Tecnico di Assistenza Via tel Data Intervento USEFUL INFORMATION 38 CUSTOMER SERVICE...

Страница 39: ...er Uno solo Un seul Only one Pi di uno Plusieurs More than one Compilare tutto in STAMPATELLO Remplir en caract res d imprimerie To write blockletters n Contratto di manutenzione programmata Abonnemen...

Страница 40: ...3520300030 Rev 1...

Отзывы: