![Italkero Fiammella Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/italkero/fiammella/fiammella_installation-manual_2094817019.webp)
Chances A1/A2 tube assemblage in wall.
This solution can be adapted when the wall thick-
ness consent to execute the trace for the connection
tubes, and can be realize in two ways:
CASE A1 (with Ø 54 mm pipes)
To install the fume exhaust and air extraction pipes:
- mark the centre (A) and make the hole B (Ø 65 mm
for the Ø 54 mm pipe).
- make the recess in the wall to house the curve and
remaining pipes.
- WALL installation: fasten the template to the wall
using the Ø 8 mm screw anchors provided. Use the
holes C.
- CORNER installation: rest and fasten the brackets
(D) above the template using the holes C. Fasten the
TBrackets to the corner walls, using the
holes E on the brackets.
With hard coverings, to house the fastening
screws of the adapter union, two recesses are
required. Use the template to mark the holes to be
made with Ø 6 mm drill.
In the case of normal plaster, simply pass a 3mm
diameter drill bit through the holes.
Before you wall up the tubes, provide to
insulate the exhaust fume tubes, with strong
materials resistant at a greater temperature of
200 °C (ex. HT/-Armaflex).
Min.
150
Min.
150
770
A
B
C
C
D
D
E
E
A1
A2
MIN
200
mm
19