![Italkero Fiammella Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/italkero/fiammella/fiammella_installation-manual_2094817025.webp)
The appliance must be installed by companies
approved pursuant to Law no. 46 dated 5 March
1990. Upon completing the installation, such compa-
nies must issue a declaration of installation confor-
mity in accordance with applicable national and local
laws (see art. 17 of law no. 46/90) and the instruc-
tions provided by the Manufacturer in the installer's
booklet attached to the product.
The convectors are fully wired in the factory and
complete with plug for connection to the power
mains.
Only a HAR H05 RRF type power cable need be
made with MIN cross section of 1 mm, using, for
connection to the appliance, the socket provided and
making an EARTH connection that is 2 cm longer
than the PHASE and NEUTRAL leads.
Connect the other end of the cable to a socket or
omnipolar switch, in conformity with CEI standards,
connected to an effective EARTH system.
A proper earth connection is mandatory.
The manufacturer of the appliance cannot be held
liable for any damage caused by lack of proper earth
connection.
For jobs of an electrical nature, always refer to the
diagram attached to this booklet.
Fit a disconnection device from the power mains
upstream of the power cable (omnipolar switch or
plug) such as to ensure a contact opening of at least
3 mm.
Unsheath the EARTH lead so this is at least 2
cm longer than the other two leads.
Never use gas and/or water pipes to earth the
appliance.
25
INSTALLER
POWER CONNECTIONS
L
N
+ 2cm
N
L