Removing the casing
Remove the retention screws (1 or 5) depending on the
cover (2 or 4) chosen according to the jobs to be done.
Very carefully remove the front or rear panel (3) as
shown in the front and rear panel Assembly and
removal Chapter.
To remove the front panel (3), there is no need
to remove both covers (2 and 4). Removing just
one of these is enough.
Fitting the casing back on
Fit the casing back on in the reverse sequence to
removal,
with special care given to fitting the
panel (3) back on.
36
CUSTOMER SERVICE
DISASSEMBLY & RIASSEMBLY OF THE SKIRT
FAULT
CAUSE
REMEDY
Installed nozzles not suitable for
gas used
Fit right nozzles
Control board faulty
Replace
Power supply disconnected /
Check.
The appliance does not start
Incorrect gas pressure
Set correct pressures
Thermostat fails to engage
Adjust the thermostat
Burnt-out fuse
Replace
Control board faulty
Replace
High room temperature
Room thermostat set too high.
Air in gas pipes
Bleed
Incorrect ignition electrode
distance
Reset the correct distance
The appliance fails to start
(appliance not working properly /
blocked)
Nozzles dirty
Clean nozzles
Gas valve closed
Check / Replace:
- Safety thermostat tripped (tang.
fan or faulty thermostat, gas
setting)
- Valve faulty
No signal from pressure switch.
Check/Replace:
- not suitable pipes (diameter, length,
curves, fitting)
- pressure switch (operation/connections)
- small pipes (cleaning)
- centrifugal fan (connection/operation).
Wrong programming
Adjust the program.
The timer does not engage or
does not work
Wrong function programming
Position on "AUTO"
Power supply switch OFF.
Reset and re-programme the timer.
Wireless synchronization inactive
Synchronize the Wireless
2
4
1
3
5
EVENTUAL ANOMALY
Содержание faro
Страница 1: ......
Страница 40: ...3520300031 Rev 2...