Replacing the SIT gas valve
Follow the instructions below to remove and refit the
valve:
- remove the power connections.
- loosen the retention nut that secures the burner
pipe (1) to the valve body (2).
- loosen the retention nut that secures the mains gas
pipe to the valve body.
- loosen the retention fork screw and remove it.
- remove the faulty valve by sliding off carefully.
- fit the new valve, being careful to position this cor-
rectly.
- fit the power and gas connections back on.
Pressure switch replacement
Follow the indication to replace the Pressure switch
- Extract the pressure switch (1) from support (2)
-Take off the tubes (3 & 4) and the electrical connec-
tors from the pressure switch.
- Unscrew the stirrup support fixing screw (2) separa-
ting the pressure switch from the frame.
-Reassemble the new pressure switch
-Insert the silicone tubes (3 o 4), also be real careful
when you reconnect the cables, if you are not sure of
what you are doing look at the electrical diagram.
Always remember, to use original spare parts.
Replacing the condenser
Follow the instructions below to remove and refit the
fan condenser:
- take out the damaged condenser (1)
- replace the component part and fit it back, perfor-
ming removal operations in the opposite sequence.