Fan replacement
Follow the indication to replace the fan
- Take off the electrical connectors that are on the
fan motor (1).
- Take off the ground connector that is on the fan
motor.
- Unscrew the screws (2) that fasten the fan to the
supports (3)
- Replace the fan then after do the assemblage
Replacing a burnt out protection fuse
In the event of the appliance not switching back on
after a short circuit, immediately check the condition
of the protection fuse and proceed as follows:
- remove the external cover (1) of the Flame Control
board;
- remove the fuse (2) and check its condition. If it has
gone brown or the inside filament is broken, it will
have to be replaced with another of the rapid type:
F1AT- 250 V.
Comburant air fan replacement.
Follow the indication to replace the comb rent air fan.
- Take off the electrical connectors from the motor.
- Take off the electrical ground connectors from the
motor.
- Remove the tube (1) from the pressure tap.
- Disassemble the clamp (2) unscrewing the screws (3)
divide the clamp with the sleeve in two parts (4) fasten the
fan metering screw (5) to the combustion chamber (6).
- Disassemble a half sleeve (4) with the clamp (2) and
after the fan (5).
- Unscrew the screw away the fan frame complete of
curves connector (7) and ant vibration gasket (8).
- Disassemble the curves connector (7) from the mete-
ring screw of the broken fan and reassemble (complete
of ant vibration gasket (8) on the new component.
- Reassemble the fan in the reverse way being careful
of inserting before the curves connector complete of O
Ring (9) in the intake tube.
- Lock the clamp well, (2) until the sleeve (4) in rubber
can seal the collegaments of the fan, then fastens well
the fan frame with the screw represtinig the electrical
connector and reconnecting the pressure tap.
Electrodes replacement
Follow the indication to replace the electrode.
- The ignition electrode (1) and revelation (2) half to
be cleaned real carefully, after a period of time they
get fragile because of the work they which they do.
- Take off the high-tension cable
- Unscrew the screws (3) and extract the electrode
group
- Reassemble the electrode (1 o 2) with the reversed
sequence of the assemblage replace the seal gasket
(4) be real careful at not damage the electrodes
ceramic insulator.
-Reconnect the cables on the processor control box
(P.C.B assy).
8