background image

Содержание faro

Страница 1: ......

Страница 2: ...ERAL COMPLIANCE Our appliance are compliance at Gas directive 90 396 CEE Electromagnetic directive compatible 89 336 CEE Low tension directive 73 23 CEE 0694 RANGE F a r o MODEL CODE F R 7 0 R 2 M 0 0...

Страница 3: ...l be long lasting reliable when it is installed and used properly manufacturer s guidelines are followed Good work and thanks The Manufacturer 3 GENERAL WARRANTY Provided that it is fitted in accordan...

Страница 4: ...heated pag 19 54 mm pipes with single end piece pag 19 Diaphragms assemblage pag 23 Fitting the remote digital control pag 24 Electrical collegaments pag 25 Gas connection pag 26 CUSTOMER SERVICE Prel...

Страница 5: ...nt to Art 17 of law no 46 90 and the instructions provided by the Manufacturer in the installer s booklet that accompa nies the product The appliance must be used as intended by the Manufacturer and f...

Страница 6: ...f the apparatus The appliance is a gas radiator that heat up the atmosphere It has an intake of air that goes in the combustion chamber type C The appliance is made with an aluminium body that allows...

Страница 7: ...ectrode 11 Pressure switch 12 Combustion chamber 13 Combustion fan 14 Garter spring 15 Power plug 16 Technical data plate 17 Gas valve 18 Gas tap 19 Manual control 20 Control unit 21 On Off switch 22...

Страница 8: ...convector in box Terminal capacity reduction Qn Terminal power convector nomination Pn Terminal power convector reduction Pn Reduce nozzle pressure Main pressure nomination DESCRIPTION CODE 90 curve...

Страница 9: ...T CN T1 VT TA BL WH RD SC EA ER EV1 F CL EV2 L N PS TL EP CVT SPLIT ROOM PROBE COMBUSTION FAN TANGENTIAL FAN CONNECTOR POWER TERMINAL TANGENTIAL FAN IGNITION TRANSFORMER BLUE WIRE WHITE WIRE RED WIRE...

Страница 10: ...flashing Wireless default transmission about 2 5 minutes 4e GREEN Led flashing Wireless data transmission by the change of any parameter 5 Wireless On button switch press and hold 2 seconds LED 4 star...

Страница 11: ...sists of Q ty Description 1 90 curve in cast aluminium 1 90 curve in aluminium 1 Gas tap with connections 2 Pipes 54 mm L 500 mm 1 Single end piece with integrated rosette 4 6 mm screw anchors for fas...

Страница 12: ...fastened to a wall as an extension of same B between two perpendicular walls C in the middle of a wall D in the centre of an environment 12 INSTALLER mm 2157 mm 680 mm 312 kg 58 faro Height B Width C...

Страница 13: ...nce tubes there are mate rials that can support the heath second check if the wall is made of the right material and can support the appliance weight Verified if around the exhaust fumes tubes there i...

Страница 14: ...bar so that you can see the tubes we recommend that the unloaded tubes 1 have to have a good insulation using materials that have also a resistant of more 200 C ex HT Armaflex of temperature Realize t...

Страница 15: ...he extraction pipe that runs along the entire side upright of the appliance During the drilling operations be very careful not to damage drill the gas pipes and wiring harnes ses passing along the sid...

Страница 16: ...ng the weight of the appliance taking into account above all the material from which the wall is made fasten the appliance in the desired position Use the anchors most suitable for suppor ting the wei...

Страница 17: ...on regulate the overhang of the L shaped plate 1 with respect to the bracket 4 then tighten the screw 2 well so as to keep the panel up against the frame causing it to adhere properly on the seal 6 on...

Страница 18: ...t the pipes and any corner curves in the wall without the single end piece position the extraction exhaust pipes flush with the outer wall being careful that the exhaust pipe 1 is always higher than t...

Страница 19: ...an be summed up in the three examples described in this chapter Before assembling the Pipes check complian ce with MAX pipe length and MAX accepta ble flow resistance see Chart Sum of the pressure lea...

Страница 20: ...ted by two kinds of tubes 54 mm With 54 mm tubes Adapt the length tube to the wall space so it increases 25 mm then cut it the adapter connection unit is already fitted on the top part of the applianc...

Страница 21: ...adapter preparation is effected by two kinds of tubes 54 mm With 54 mm tubes Adapt the length tube to the wall space so it increases 25 mm then cut it the adapter connection unit is already fitted on...

Страница 22: ...stant to temperatures above 200 C eg HT Armaflex Adapter pipe connection unit with 54 mm pipes Adapt the length of the fume exhaust pipe to the thickness of the wall increased by 25 mm cutting the ex...

Страница 23: ...g HT Armaflex Chimneypot assemblage To assemble the chimneypot on the unloaded intake tubes use the clamp 1 and the 2 safety screw The chimneypot application has to satisfy the fol lowing requirement...

Страница 24: ...the limit of the range of action C If the LED does not flash you are outside the range of action mark the position of the fastening holes on the wall and drill fit the screw anchors and screws most s...

Страница 25: ...socket provided and making an EARTH connection that is 2 cm longer than the PHASE and NEUTRAL leads Connect the other end of the cable to a socket or omnipolar switch in conformity with CEI standards...

Страница 26: ...to realize a good ground connection and to respect the neutral phase During the first starting you might verify vapour and irritating smells not dangerous To avoid these discomfort we advice to aerat...

Страница 27: ...ature In case of malfunctions in startup procedure or ope ration the appliance STOPS and the relevant unblock signal lights up on the display Reset the appliance by keeping the unblock button pressed...

Страница 28: ...ed that the gas pressures are as under the Table The gas pressure value has to be as in the table The apparatus execute a stop and next restart Operating from the main control panel Operate on the atm...

Страница 29: ...urner 5 and disk 8 Unscrew the 3 injectors 6 change them with the new ones Be real careful when you fasten the injec tor check on the injector that it has the right values as in the table The injector...

Страница 30: ...nimum pressure are as spe cified in the table To make a regulation operate on the screw that is on the modulator body 4 Rotating the regulator screw 3 clockwise the pressure decrease rotating counter...

Страница 31: ...h to the off position Close the gas tap Wait that the appliance gets cold completely Cover clean The only cleaning that is required by the owner involves removing the cover and wiping it clean the dus...

Страница 32: ...ittle brush with metallic hair for cleaning after insert the electrode group 1 o 2 if necessary exchange the seal gasket 4 be real careful to not damage the electrode Pressure switch tubes Check that...

Страница 33: ...mbustion chamber 6 Disassemble a half sleeve 4 with the clamp 2 and after the fan 5 Unscrew the screw away the fan frame complete of curves connector 7 and ant vibration gasket 8 Disassemble the curve...

Страница 34: ...trips if the convection fan is not working properly or anomalous overheating occurs and or the outflowing air temperature reaches over 107 C disengaging the burner closing the gas valve and stopping...

Страница 35: ...the Pressure switch Extract the pressure switch 1 from support 2 Take off the tubes 3 4 and the electrical connec tors from the pressure switch Unscrew the stirrup support fixing screw 2 separa ting t...

Страница 36: ...essure Set correct pressures Thermostat fails to engage Adjust the thermostat Burnt out fuse Replace Control board faulty Replace High room temperature Room thermostat set too high Air in gas pipes Bl...

Страница 37: ...nd regulate the gas replace Power of appliance not enough for installation premises Replace the appliance with a more powerful one Faulty control board Replace The tangential fan does not work Faulty...

Страница 38: ...Seller Street tel Sir Installer Street tel Sir Technical Service Assistance Street tel Date Intervention USEFUL INFORMATION 38 CUSTOMER SERVICE...

Страница 39: ...er Uno solo Un seul Only one Pi di uno Plusieurs More than one Compilare tutto in STAMPATELLO Remplir en caract res d imprimerie To write blockletters n Contratto di manutenzione programmata Abonnemen...

Страница 40: ...3520300031 Rev 2...

Отзывы: