INSTALLER
FAULT
CAUSE
SOLUTION
Gas valve closed
Check/replace
- Faulty valve
The pilot doesn’t light up
Check / switch /replace
- Improperly set electrode gap
- Selector knob set to incorrect position
- Dirty pilot injector
The appliance does not start
(does not run)
The appliance starts
(malfunction/shutdown)
Injectors not suited to the gas type
Use the proper injectors
The pilot does not stay on
Check / switch /replace
- Thermocouple failure
- Dirty pilot injector
Uneven gas pressure
Set the proper pressures
Room temperature greater than
programmed value
Set room thermostat to 7
Air in the gas line
Purge the pipes
Burned fuse
Replace
Dirty injectors
Clean the injectors
Timer has not effect, not working
Segments out of position
Adjust the segments
Mains power disconnected
Check the power supply
Function switch in the wrong position
Set to timer
Power switch set to OFF
Reset and program the timer