INSTALLER
if you need to replace any parts (pcb's, valves,
thermostats, pressure switches, fans, etc.) use only
original spare parts supplied by the manufacturer.
Convection fan
Remove and restore the fan as follows:
- remove the electrical connections on the fan motor;
- remove the earth connection on the motor;
- undo the four screws securing the fan mounts to the
heater's back frame and extract it;
- install a new unit in reverse order: first install the
mounts, including dampers, to the slots, then secure it
to the frame and restore the electrical connections to
prevent malfunctions (such as incorrect speeds or short
circuits).
Fuse burnt out
If the appliance does not turn on again following a short
circuit, check the fuse as follows:
- undo the cap (1), and extract it.
- remove the fuse (2) and check it; if it is burnt or the
filament is broken, replace it with another rapid fuse:
1A-250 V.
Electrode
Remove and restore the ignition electrode as follows:
- disconnect the high voltage cable from the electrode
connector
- undo the collar (6) and extract the electrode (7);
- fit a new electrode in reverse order; it will only fit in one
position;
- take care not to damage the ceramic insulation.
rePlacing comPonents