17
INSTALLER
intake/flue PiPe assembly and gas
connection
- Cut the pipes to length to suit the thickness of the wall,
as shown in the figure.
IMPORTANT: the outer steel pipe must be cut to the
same length as the thickness of the wall.
IMPORTANT: cut the inner pipe (flue) so that, when it is
installed, it is aligned outwardly with the external pipe
and protrudes by 10 mm from the interior wall. Cut the
pipe using the adhesive cutting tape as a guide stuck to
the pipe at the position of the cut itself.
IMPORTANT: Cutting must be perpendicular to the pipe
axis, please handle with care in order not to deform the
pipes.
Insert the outer pipe through the hole, then fit the inner
pipe into the outer one.
- Insert the flue/intake terminal onto the concentric
pipes; mark the centres of the four holes for the 6 mm
wall mounting plugs.
- Remove the terminal, drill the four 6 mm holes, and fit
the plugs into them.
- Fit the terminal onto the concentric tube and secure it
tightly to the wall with the wall screws.
IMPORTANT: if the outside pipe protrudes from the
wall (terminal not snug against wall), the burners may
malfunction and even go out or shut off the pilot light,
especially in bad weather (strong wind, rain, etc.).
10
mm
25
mm
67
mm
Содержание Eco SC Series