Convection fan thermostat
To remove and restore the thermostat (3):
- remove the thermostat bracket (1) by undoing the
screw (2);
- disconnect the thermostat's electrical connectors;
- restore the thermostat in reverse order;
The thermostat runs the convection fan when the intake
air reaches 45°C.
make sure to fit a thermostat with the correct
calibration.
Safety thermostat (manual re-arm)
To remove and restore the thermostat (3):
- to facilitate access to the thermostat, take off the cover
(4) by undoing its screws.
- remove the thermostat bracket (1) by undoing the
screw (2);
- disconnect the thermostat's electrical connectors;
- restore the thermostat in reverse order;
The safety thermostat trips when the convection fan is
not running properly, the appliance is overheating, or
the output air is hotter than 107 °C, and turns off the
burner, closes the gas valve and shuts the appliance
down.