EASY MIX PLUS
- 37 -
Easy Mix Plus - 2018/07 - Rev. 03
EN
6. MAINTENANCE
WARNING
Never put your hands into the machine during production and cleaning operations.
Before carrying out any maintenance operation, make sure that the machine is in
“
STOP
” position and main switch has been cut out.
6.1
SERVICE TYPE
WARNING
Every maintenance operation requiring opening of the machine panels must be carried out
with machine stopped and disconnected from the power supply!
It is forbidden to clean and lubricate moving parts!
"Repairs to the wiring, mechanical, air supply or cooling systems, or to parts of same must be
carried out by qualified and authorized personnel and if necessary, according to the routine
and extraordinary maintenance schedules as envisaged by the customer with reference to
specific operation methods, according to the use for which the machine is destined".
Operations necessary for correct machine operation are such that most of routine maintenance
operations are integrated into the production cycle.
Maintenance operations, such as cleaning of parts in contact with the product, replacing of seals,
disassembling of beater assembly are to be carried out at the end of the working day, so as to
speed up maintenance operations required.
Below is a list of ordinary maintenance operations:
- Hopper and lid cleaning.
It must be carried out at the end of each shift.
- Beater unit cleaning
It must be carried out at the end of each shift.
- Cleaning of panels
To be carried out daily with neutral soap, seeing to it that cleansing solution never reaches
beater unit at its inside.
- Cleaning and sanitization
At the end of every working day, according to procedures described in section 5 of this manual.
WARNING
Never use abrasive sponges to clean machine and its parts, as they might scratch its
surfaces.
6.2
WATER COOLING
By machines with water-cooled condenser, water must be drained from condenser at the end of
selling season in order to avoid troubles in the event that the machine is stored in rooms where
temperature may fall under 0 °C.
After closing water inlet pipe, disconnect the drain pipe from its seat and let the water flow out
from the circuit.
6.3
AIR COOLING
Clean condenser, periodically, so as to remove dust, paper and whatever prevents air from
circulating. For cleaning, use a brush with long bristles or a bolt of compressed air.
ATTENTION!
When using compressed air, use personal protective devices in order to avoid accidents;
wear protective goggles.
Note
: Never use sharp metal objects to carry out this operation; the correct operation of a
refrigeration system largely depends on how clean the condenser is.