Base display
-
With the card in standby it shows the temperature of the bottom element.
-
With the cooking cycle in progress it shows the temperature of the bottom element.
-
With cycle setting in progress it shows the set-point for the bottom element.
-
With weekly programming in progress it shows the program number.
PROG. display
-
Shows the number of the selected program (from one to nine). The horizontal dash
indicates the manual program.
LED
Led ON/OFF
-
The Led is on if the card is turned Off, but is supplied with power.
-
The Led flashes while the cycle is in progress.
Ceiling led
-
The Led is on if the Top heating elements are on.
Base led
-
The Led is on if the Bottom heating elements are on.
Humidity led
-
The Led is on if the humidity is on and ready to generate steam.
-
The Led flashes if the humidity is on but not yet up to temperature.
-
The Led is off if the humidity is not on.
LIGHT Led
-
The Led is on if the chamber light has been switched on by pressing the LIGHT button.
LOGO ITALFORNI led
-
The led is off if the card is in off, or it’s on if the card is in or the cooking cycle is in progress.
4.2.2 Operations
I^ SWITCHING ON
Referring to the I^ switching on it’s necessary to set DATE and HOUR to set up the baking
temperature.
NOTES : if the oven is not connected up to the electricity network for more than 72 hours, it could
be necessary to set up again DATE and HOUR.
SWITCHING ON
When the card is off, all the Leds and displays are turned off except the TIME display, which shows
the current time.