SATA II RAID Subsystem
90
User Manual
5.6.3 Hardware Monitor
To view the RAID subsystem’s hardware information, click the
Hardware Monitor
link
from the
Information
menu. The Hardware Monitor Information screen appears.
NOTE: To disable auto refresh of GUI, tick the “Stop Auto Refresh”
option.
The Hardware Monitor Information provides information about controller, enclosure 1 and
enclosure 2, such as the temperature, fan speed, power supply status and voltage levels.
All items are also unchangeable. When the threshold values are surpassed, warning
messages will be indicated through the LCD, LED and alarm buzzer.
Item
Warning Condition
CPU Temperature
> 90 Celsius
Controller Board Temperature
> 70 Celsius
HDD Temperature
> 65 Celsius
Fan Speed
< 1500 RPM
Power 12V
< 10.5V or > 13.5V
Power 5V
< 4.7V or > 5.4V
Power 3.3V
< 3.0V or > 3.6V
DDR Supply V2.5V
< 2.25V or > 2.75V
CPU Core V1.3V
< 1.17V or > 1.43V
DDR Termination Power +1.25V
< 1.125V or > 1.375V