Operating
Your Spa
17
Setting Filtration Cycles
Your spa is programmed to filter twice a day. The first
cycle will begin 6 minutes after the spa is turned on
and the second cycle 12 hours later. The factory has
programmed the cycle to last for 2 hours but this can be
switched to 4, 6, or 8 hours depending on your require
-
ments. The default filter time is two hours.
To set filtration time, turn off the power to the spa
at the time of day you would like one of the filtration
cycles to begin, then turn back on after 30 seconds.
When power has been restored, press either the
Up
or
Down
button then the
Jets
button. Press either the
Up
or
Down
button again to change the filtering cycle
duration. When desired duration is selected press the
Jets
button to exit.
The low speed pump will run for the duration of the
filtering cycle and if an ozone system is installed it will
be activated. During filtering,
FC
will appear on the
main display.
Diagnostic Messages
Message
Meaning
Action Required
No message
on display
1) Spa temperature is unknown.
1) After pump has been running for 2 minutes tempera-
ture will be displayed.
2) Spa is in Economy or Sleep mode.
2) In Economy or Sleep mode, the pump may be off for
hours outside a filter cycle. If you wish to see the current
spa temperature, either switch to Standard mode or turn
Jets1 on for at least two minutes.
3) Power has been cut off to the spa.
3) The control panel will be disabled until power returns.
Spa settings and time of day will be preserved for 30
days with a battery back-up.
dr
Insufficient water detected in heater. Spa
will be shut down for 15 minutes.
Check water level in spa. Refill if necessary. Make sure
pumps are been primed and filter cartridges are clean.
Press any button to reset or wait 15 minutes and spa will
automatically reset. If message spa does not reset, call
your dealer or service organization.
drY
Insufficient water detected in heater. Spa
is shut down.
(Displays on third occurrence of dr mes-
sage.)
Follow directions for dr message and press any button to
reset spa. Spa will not automatically reset when dry or
dY is displayed.
Ec
Indicates heater is in Economy Mode.
None.
--
Temperature unknown
After the pump has been running for two minutes, the
temperature will be displayed.
HFL
A difference in readings between tem-
perature sensors has been detected
indicating a possible water flow problem.
Make sure spa is filled to proper level and that pumps
are primed and filter cartridges are clean. If message
does not reset, call your dealer or service organization.
Your new spa comes equipped with an electric heater.
Following the directions listed below will ensure the
most efficient operation:
NOTE: This method is only for spa usage under two
hours a week.
Keep the spa’s operating temperature 5˚F below
•
the desired usage temperature when not in use.
One or two hours before use, set the tempera-
ture to the desired temperature.
If the spa usage exceeds two hours a week, the
•
set temperature should remain at the desired us-
age temperature.
Allowing the water temperature to lower more than
10˚F below the desired usage temperature and re
-
heating it prior to usage will cause the heater to op-
erate longer than it normally would maintaining the
desired temperature. Doing this will increase your op-
erating cost and makes your heater work more than
necessary.
Содержание PORTABLE SPA 2009
Страница 1: ...LTR20091084 Rev A 9 1 09 Preliminary...
Страница 10: ...2009 iSpa Owner s Manual LTR20091084 Rev A Preparing for Your New Portable Spa 8 GFCI Wiring Diagram...
Страница 11: ...Preparing for Your New Portable Spa 9...
Страница 23: ...Operating Your Spa 21...
Страница 46: ...2009 iSpa Owner s Manual LTR20091084 Rev A Appendix 44...
Страница 47: ...Appendix 45...