The configuration of the UVC TWIST number and the relative control console must be agreed upon when
ordering. The instructions given in this manual are for descriptive purposes only for the assembly and use
of the product.
CONNECTION TO THE ELECTRICITY NETWORK
As indicated above, the UVC TWIST and control console components do not have electrical connections that connect them together
as the installation positions and therefore the cable lengths are not known.
Any requests for customization with specific lengths must be indicated when ordering.
The UVC TWIST modules are connected to the control console and to each other with the following types of electrical cables.
INPUT control console> cable 3x1.5mm² Control console power supply on terminals n ° F - N and grounding of the terminal board
terminal F is equipped with a fuse with a value of 3.15A
OUTPUT control console> INPUT I ° UVC TWIST
cable 3 x 0.75mm² ballast power supply 230Vac UVC lamp inside UVC corner
from terminal n ° 3 of the 230V phase console> to terminal n ° 9 of the electrical panel inside the Twist
from the ground terminal of the console> to the ground terminal of the panel inside the Twist
from terminal n ° 4 of the 230V neutral console> to terminal n ° 10 of the electrical panel inside the Twist
This connection is through in the case of sequential connections of several ceiling lights
Passage for IN and OUT con-
nections on the control console
Wall-mounted electrical panel for control console
F
2
3
4
5
6
7
8
hour counter
230Vac-12Vdc power supply
Lamp relay
WARNING!
After operating the switch,
wait 1 minute before starting
the sanitizing cycle to allow
the automatic setting of the
IR sensors
16
Exit time selection
timer
1
N
Terminal F has a 3.15 A fuse
Block relay
safety
Twist electrical panel
9
13
12
11
10
14
15
17
18
19
20
21
F1
Terminal F1 is equipped with a 1A fuse
The following connections are also present in the
electrical panel of the Twist
C1 which connects the UVC lamp group
C2 which connects the IR sensor
C3 which connects the opening limit switch of the
gearmotor
C4 which connects the closing limit switch of the
gearmotor