TWIST COMPONENTS DESCRIPTION
CAUTION!!
UNPACKING, ASSEMBLY, INSTALLATION AND COMMISSIONING OF THE VARIOUS COMPONENTS
MUST BE PERFORMED BY TECHNICAL PERSONNEL ONLY
REMOVAL OF PACKAGING
The components that make up the assembly kit are supplied with adequate external packaging.
During the unpacking operations, be careful not to damage the surfaces and the particular places
inside the packaging as they are delicate against bumps and scratches.
Keep the packaging for the duration of the warranty. The packaging materials must then be disposed of in accor-
dance with the regulations in force in the country of destination of the product.
Before proceeding with the installation, check the integrity of the devices; in case of transport damage,
contact the retailer.
Warning!
The product uses potentially dangerous UV radiation; do not use the product in the presence of people or
other living beings in the “Cleaning Surface” mode; EYE AND SKIN DAMAGE ARE POSSIBLE.
THE PRODUCT IS INTENDED ONLY AND EXCLUSIVELY FOR INTERNAL USE AND IS NOT SUITABLE
FOR HUMID ENVIRONMENTS
TO AVOID THE RISK OF FIRE OR ELECTRIC SHOCK, THE APPLIANCE MUST NOT BE USED WHERE
CONTACT WITH WATER IS POSSIBLE.
THE APPLIANCE MUST NOT BE USED IN POTENTIALLY EXPLOSIVE ATMOSPHERES.
UVC TWIST
module with passive IR sensor
for detecting the presence of people.
INSTALLATION
TWIST + Command console
Control console composed of:
•
a metal support where the electrical compo-
nents are housed
•
closing cover with adhesive serigraphy on
which the timer, the reset button and the switch
for selecting the operating mode are incorporated.
A single control system can manage several UVC TWIST modules up
to a maximum of 5.
The positioning of the UVC Corner module must be carried
out considering the following aspects to avoid anomalous in-
terventions of the safety systems.
Since a passive infrared PIR sensor is used, it is necessary:
•
Avoid positioning where there may be interference with systems
that have sudden changes in temperature (eg radiators, air condi-
tioners, fireplaces, stoves and the like).
•
Avoid direct exposure to sunlight.
•
Avoid positioning towards particularly close reflective surfaces.
•
Avoid positioning in rooms where there is a high presence of fumes / fog, such as to cause condensation;
IT IS RECOMMENDED TO DIRECT THE PRESENCE DETECTOR TOWARDS THE ENTRANCE OF THE ENVI-
RONMENT WHERE THE UVC TWIST MODULE IS INSTALLED