background image

 

 

Warranty is Subject to Compliance with Specific Installation Requirements.

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Specifications: 

 

Control Panel - Stainless Steel 16 gauge            
 

  

8.375 X 16.50  

 

        

Wall Box – 16 gauge powder coated sheet metal   

             6.0 X 14.25 X 4.0 

 

      * all dimensions are in inches 

 
 
 
 

.

 

 

Style 

# Output 

Circuits 

Trans-

former 

Switch\ 

Breaker 

pcb 

Fuse 1 

Output Rating 

(standard) 

Pulse Output 

DLA -2 

1  @ 24 vac 

2 amp 

5 amp 

2 amp 

2 amp @ 24 vac 

2 @ 12 vdc 

DLA -2 

1  @ 24 vac 

3 amp 

5 amp 

3 amp 

2 amp @ 24 vac 

4 @ 12 vdc 

 

Output fuse on PCB, FUSE 1 is Slow Blow.  PCB circuit fuse, FUSE 3 is 500 mA Fast Acting 

 

Содержание DLA Series Style 2

Страница 1: ...esting Labs Style 2 W Ver 4 41 pcb Pulse Relay pcb s Installation Operations Start up and Maintenance Instructions Table of Contents Page Warranty 2 Enclosure Specifications and Dimensions 3 Styles 3...

Страница 2: ...period of two years from date of installation when installation complies with all start up and routine maintenance procedures and Start up has been performed by an authorized factory representative R...

Страница 3: ...owder coated sheet metal 6 0 X 14 25 X 4 0 all dimensions are in inches Style Output Circuits Trans former Switch Breaker pcb Fuse 1 Output Rating standard Pulse Output DLA 2 1 24 vac 2 amp 5 amp 2 am...

Страница 4: ...ening From within the cabinet fit into opening and fasten unit to back of casework Face of wall box should be even with face of cabinet After mounting unit protect interior of box from construction de...

Страница 5: ...valves Connect both supply valves to pins 4 5 or Utilize when one 1 supply and one 1 drain down solenoid is provided Connect supply valve to pins 4 5 Connect drain down to pins 6 7 Figure 2 Utilized...

Страница 6: ...n counter clockwise the two retaining clips at the top of the Panel and open Insert plug onto circuit header on PCB Turn Power ON Close the panel and lock CAUTION Do not install the panel until all wa...

Страница 7: ...he piping system continues to function properly If you have any questions regarding the operation and maintenance of the DLA Controller please contact an ISIMET Service Representative The enclosure ha...

Страница 8: ...logy ISIMET believes that sole and local authority means that the primary operator or the instructors should have the sole authority to start and stop the utility services within the immediate area of...

Отзывы: