Warranty: 
ISIMET
 will repair or replace any defective parts or workmanship of this product for a period of one year 
from date of installation.  The P.C. Board has a two year limited warranty.

  

Damage caused by incorrect 

installation or improper usage is not warranted.  Failure to follow recommended installation, operation, 
and/or maintenance procedures listed in this manual may void product warranty.  Recovery rights shall be 
limited to the total sum of the amounts paid for the product by the purchaser.   

 

EXTENDED WARRANTY: 
ISIMET
 will extend the warranty of this product to a period of two years from date of installation when 
installation complies with all start up and routine maintenance procedures and Start up has been performed 
by an authorized factory representative.  Refer to Extended Warranty Policy.

 

 

Limits of Liability: 
ISIMET's
 liability shall be limited to costs of repair or replacement parts.  The Laboratory Service Panel and 
Utility Controller are not intended for usage other than those expressly described in this manual.  ISIMET
 
shall not be liable for damage or injury caused by the improper use of the product. 
 
ISIMET
 does not warrant against or assume liability for failure of operation or lack of notification to 
secondary integrated monitoring systems.  The system should be thoroughly tested and adjustments made at 
time of initial operation.  Periodic testing should be conducted by the user to assure that all components 
function and operate according to specifications. 
 
Care should be taken in the installation of this product.  ISIMET
 shall not be liable for damage or injury 
caused from the improper installation of the product. 
 
Warranty is Subject to Compliance with Specific Installation Requirements. 

 

DISCLAIMER OF IMPLIED WARRANTY: 
THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION HEREIN.  SELLER 
DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OF THE GOODS OR OF THE 
FITNESS OF THE GOODS FOR ANY PURPOSE, AND BUYER AGREES THAT THE GOODS ARE 
SOLD “AS IS.” 

 
 

 

 

 

Содержание DLA Series Style 2

Страница 1: ...esting Labs Style 2 W Ver 4 41 pcb Pulse Relay pcb s Installation Operations Start up and Maintenance Instructions Table of Contents Page Warranty 2 Enclosure Specifications and Dimensions 3 Styles 3...

Страница 2: ...period of two years from date of installation when installation complies with all start up and routine maintenance procedures and Start up has been performed by an authorized factory representative R...

Страница 3: ...owder coated sheet metal 6 0 X 14 25 X 4 0 all dimensions are in inches Style Output Circuits Trans former Switch Breaker pcb Fuse 1 Output Rating standard Pulse Output DLA 2 1 24 vac 2 amp 5 amp 2 am...

Страница 4: ...ening From within the cabinet fit into opening and fasten unit to back of casework Face of wall box should be even with face of cabinet After mounting unit protect interior of box from construction de...

Страница 5: ...valves Connect both supply valves to pins 4 5 or Utilize when one 1 supply and one 1 drain down solenoid is provided Connect supply valve to pins 4 5 Connect drain down to pins 6 7 Figure 2 Utilized...

Страница 6: ...n counter clockwise the two retaining clips at the top of the Panel and open Insert plug onto circuit header on PCB Turn Power ON Close the panel and lock CAUTION Do not install the panel until all wa...

Страница 7: ...he piping system continues to function properly If you have any questions regarding the operation and maintenance of the DLA Controller please contact an ISIMET Service Representative The enclosure ha...

Страница 8: ...logy ISIMET believes that sole and local authority means that the primary operator or the instructors should have the sole authority to start and stop the utility services within the immediate area of...

Отзывы: