background image

 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Wall Panel Terminal            Mounting Brackets (2) 

Mounting 
Screws

 

(4)

 

Mounting Instructions: Flush Wall Mount 
 

Two mounting flanges with screws are provided with the 
unit.  Attach flanges as shown.  Flanges can be affixed to 
any two corners of the unit.  Then, fasten unit between two 
(2) wall studs.  The face of the box should be even with the 
face of finished wall surface. After mounting unit, protect 
interior of box from construction debris. 
 
CAUTION:  Provided mounting hardware must be used.

 

Mounting Instructions: Casework Mount 
 

Two mounting flanges with screws are provided with unit.  
Holes are slotted to permit adjustments for variations in 
cabinet material thickness.  Attach flanges as shown in 
figure above.  Make cutout in desired location in casework 
to permit wall unit to pass easily into opening.  From within 
the cabinet fit into opening and fasten unit to back of 
casework.  Face of wall box should be even with face of 
cabinet.  After mounting unit, protect interior of box from 
construction debris. 
 
CAUTION:  Provided mounting hardware must be used.

 

Mounting Instructions: Surface Mount

 

 
In order to surface mount the unit, it is necessary to attach 
the provided brackets to the rear of the housing. Care should 
be taken to verify that the mounting means securely fastens 
the unit to the wall surface.  A stainless skirt is provided in 
order to conceal the wall box from view. 
 
CAUTION:  Provided mounting hardware must be used 

 

Mounting the Wall Panel: 

 

 

Verify that Unit is wired with junction box cover in 
place. 

 

With the Door open, position the Wall Panel over the 
Wall Box as shown.  

 

Holding panel in front of box, affix panel to box using 
four (4) 8-32 stainless screws 

 

Close the panel and lock. 

CAUTION!  

Do not install the panel until all wall finishes 

are complete.

 

 
 
 
 

 

Output  
Terminal 

Wall 

 

Содержание DLA Series Style 2

Страница 1: ...esting Labs Style 2 W Ver 4 41 pcb Pulse Relay pcb s Installation Operations Start up and Maintenance Instructions Table of Contents Page Warranty 2 Enclosure Specifications and Dimensions 3 Styles 3...

Страница 2: ...period of two years from date of installation when installation complies with all start up and routine maintenance procedures and Start up has been performed by an authorized factory representative R...

Страница 3: ...owder coated sheet metal 6 0 X 14 25 X 4 0 all dimensions are in inches Style Output Circuits Trans former Switch Breaker pcb Fuse 1 Output Rating standard Pulse Output DLA 2 1 24 vac 2 amp 5 amp 2 am...

Страница 4: ...ening From within the cabinet fit into opening and fasten unit to back of casework Face of wall box should be even with face of cabinet After mounting unit protect interior of box from construction de...

Страница 5: ...valves Connect both supply valves to pins 4 5 or Utilize when one 1 supply and one 1 drain down solenoid is provided Connect supply valve to pins 4 5 Connect drain down to pins 6 7 Figure 2 Utilized...

Страница 6: ...n counter clockwise the two retaining clips at the top of the Panel and open Insert plug onto circuit header on PCB Turn Power ON Close the panel and lock CAUTION Do not install the panel until all wa...

Страница 7: ...he piping system continues to function properly If you have any questions regarding the operation and maintenance of the DLA Controller please contact an ISIMET Service Representative The enclosure ha...

Страница 8: ...logy ISIMET believes that sole and local authority means that the primary operator or the instructors should have the sole authority to start and stop the utility services within the immediate area of...

Отзывы: